A fully automatic fiducial detection and correspondence establishing method for online C-arm calibration
- 10 May 2024
- journal article
- research article
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 20 (1) , 43-55
Abstract
Purpose Online C-arm calibration with a mobile fiducial cage plays an essential role in various image-guided interventions. However, it is challenging to develop a fully automatic approach, which requires not only an accurate detection of fiducial projections but also a robust 2D–3D correspondence establishment. Methods We propose a novel approach for online C-arm calibration with a mobile fiducial cage. Specifically, a novel mobile calibration cage embedded with 16 fiducials is designed, where the fiducials are arranged to form 4 line patterns with different cross-ratios. Then, an auto-context-based detection network (ADNet) is proposed to perform an accurate and robust detection of 2D projections of those fiducials in acquired C-arm images. Subsequently, we present a cross-ratio consistency-based 2D–3D correspondence establishing method to automatically match the detected 2D fiducial projections with those 3D fiducials, allowing for an accurate online C-arm calibration. Results We designed and conducted comprehensive experiments to evaluate the proposed approach. For automatic detection of 2D fiducial projections, the proposed ADNet achieved a mean point-to-point distance of \(0.65 \pm 1.33\) pixels. Additionally, the proposed C-arm calibration approach achieved a mean re-projection error of \(1.01 \pm 0.63\) pixels and a mean point-to-line distance of \(0.22 \pm 0.12\) mm. When the proposed C-arm calibration approach was applied to downstream tasks involving landmark and surface model reconstruction, sub-millimeter accuracy was achieved. Conclusion In summary, we developed a novel approach for online C-arm calibration. Both qualitative and quantitative results of comprehensive experiments demonstrated the accuracy and robustness of the proposed approach. Our approach holds potentials for various image-guided interventions.
Keywords
Funding Information
- National Natural Science Foundation of China (U20A20199)
This publication has 24 references indexed in Scilit:
- Online mobile C-arm calibration using inertial sensors: a preliminary study in order to achieve CBCTInternational Journal of Computer Assisted Radiology and Surgery, 2019
- Integrating spatial configuration into heatmap regression based CNNs for landmark localizationMedical Image Analysis, 2019
- New Calibrator with Points Distributed Conical Helically for Online Calibration of C-ArmSensors, 2019
- A deep learning framework for segmentation and pose estimation of pedicle screw implants based on C-arm fluoroscopyInternational Journal of Computer Assisted Radiology and Surgery, 2018
- Geometry calibration between X-ray source and detector for tomosynthesis with a portable X-ray systemInternational Journal of Computer Assisted Radiology and Surgery, 2017
- Distortion correction and calibration of intra-operative spine X-ray images using a constrained DLT algorithmComputerized Medical Imaging and Graphics, 2014
- X-ray image calibration and its application to clinical orthopedicsMedical Engineering & Physics, 2014
- Robust automatic detection and removal of fiducial projections in fluoroscopy images: An integrated solutionMedical Engineering & Physics, 2008
- A Novel System for the 3-D Reconstruction of the Human Spine and Rib Cage From Biplanar X-Ray ImagesIEEE Transactions on Biomedical Engineering, 2007
- TriangulationComputer Vision and Image Understanding, 1997