Macroscopic models of the diffusion MRI (dMRI) signal can be helpful to understanding the relationship between the tissue microstructure and the dMRI signal. We study the least squares problem associated with estimating tissue parameters such as the cellular volume fraction, the residence times and the effective diffusion coefficients using a recently developed macroscopic model of the dMRI signal called the Finite Pulse Kärger model that generalizes the original Kärger model to non-narrow gradient pulses. In order to analyze the quality of the estimation in a controlled way, we generated synthetic noisy dMRI signals by including the effect of noise on the exact signal produced by the Finite Pulse Kärger model. The noisy signals were then fitted using the macroscopic model. Minimizing the least squares, we estimated the model parameters. The bias and standard deviations of the estimated model parameters as a function of the signal to noise ratio (SNR) were obtained. We discuss the choice of the b -values, the least square weights, the extension to experimentally obtained dMRI data as well noise correction.Keywords
This publication has 40 references indexed in Scilit:
- Relationship between the diffusion time and the diffusion MRI signal observed at 17.2 tesla in the healthy rat brain cortexMagnetic Resonance in Medicine, 2013
- Monte Carlo study of a two‐compartment exchange model of diffusionNMR in Biomedicine, 2010
- Axcaliber: A method for measuring axon diameter distribution from diffusion MRIMagnetic Resonance in Medicine, 2008
- Numerical study of water diffusion in biological tissues using an improved finite difference methodPhysics in Medicine & Biology, 2007
- Biexponential parameterization of diffusion and T2 relaxation decay curves in a rat muscle edema model: Decay curve components and water compartmentsMagnetic Resonance in Medicine, 2005
- Diffusional kurtosis imaging: The quantification of non‐gaussian water diffusion by means of magnetic resonance imagingMagnetic Resonance in Medicine, 2005
- The existence of biexponential signal decay in magnetic resonance diffusion‐weighted imaging appears to be independent of compartmentalizationMagnetic Resonance in Medicine, 2004
- Diffusion in compartmental systems. I. A comparison of an analytical model with simulationsMagnetic Resonance in Medicine, 2003
- Effects of equilibrium exchange on diffusion‐weighted NMR signals: The diffusigraphic “shutter‐speed”Magnetic Resonance in Medicine, 2003
- An analytical model of restricted diffusion in bovine optic nerveMagnetic Resonance in Medicine, 1997