Background: While traditional intraoperative fluoroscopy protection relies on thyroid shields and aprons, recent data suggest that the surgeon’s eyes and hands receive more exposure than previously appreciated. Using a distal radial fracture surgery model, we examined (1) radiation exposure to the eyes, thyroid, chest, groin, and hands of a surgeon mannequin; (2) the degree to which shielding equipment can decrease exposure; and (3) how exposure varies with fluoroscopy unit size. Methods: An anthropomorphic model was fit with radiation-attenuating glasses, a thyroid shield, an apron, and gloves. “Exposed” thermoluminescent dosimeters overlaid the protective equipment at the eyes, thyroid, chest, groin, and index finger while “shielded” dosimeters were placed beneath the protective equipment. Fluoroscopy position and settings were standardized. The mini-c-arm milliampere-seconds were fixed based on the selection of the kilovolt peak (kVp). Three mini and three standard c-arms scanned a model of the patient’s wrist continuously for fifteen minutes each. Ten dosimeter exposures were recorded for each c-arm. Results: Hand exposure averaged 31 μSv/min (range, 22 to 48 μSv/min), which was 13.0 times higher than the other recorded exposures. Eye exposure averaged 4 μSv/min, 2.2 times higher than the mean thyroid, chest, and groin exposure. Gloves reduced hand exposure by 69.4%. Glasses decreased eye exposure by 65.6%. There was no significant difference in exposure between mini and standard fluoroscopy. Conclusions: Surgeons’ hands receive the most radiation exposure during distal radial plate fixation under fluoroscopy. There was a small but insignificant difference in mean exposure between standard fluoroscopy and mini-fluoroscopy, but some standard units resulted in lower exposure than some mini-units. On the basis of these findings, we recommend routine protective equipment to mitigate exposure to surgeons’ hands and eyes, in addition to the thyroid, chest, and groin, during fluoroscopy procedures.Keywords
This publication has 15 references indexed in Scilit:
- Interventional cardiologists and risk of radiation-induced cataract: Results of a French multicenter observational studyInternational Journal of Cardiology, 2013
- Leaded Eyeglasses Substantially Reduce Radiation Exposure of the Surgeon’s Eyes During Acquisition of Typical Fluoroscopic Views of the Hip and PelvisJournal of Bone and Joint Surgery, 2013
- Exposure From the Large C-Arm Versus the Mini C-Arm Using Hand/Wrist and Elbow PhantomsThe Journal of Hand Surgery, 2011
- Patient and Surgeon Radiation Exposure: Comparison of Standard and Mini-C-Arm FluoroscopyJournal of Bone and Joint Surgery, 2009
- Eye Lens Exposure to Radiation in Interventional Suites: Caution Is WarrantedRadiology, 2008
- Risk of Cataract after Exposure to Low Doses of Ionizing Radiation: A 20-Year Prospective Cohort Study among US Radiologic TechnologistsAmerican Journal of Epidemiology, 2008
- Exposure to Direct and Scatter Radiation with Use of Mini-C-Arm FluoroscopyJournal of Bone and Joint Surgery, 2007
- Radiation Exposure in Hand Surgery: Mini Versus Standard C-ArmThe Journal of Hand Surgery, 2005
- Radiation Exposure to the Hands From Mini C-Arm FluoroscopyThe Journal of Hand Surgery, 2005
- Exposure of the orthopaedic surgeon to radiation.Journal of Bone and Joint Surgery, 1993