Jena Reference Air Set (JRAS): a multi-point scale anchor for isotope measurements of CO2 in air
Authors:
- M. WendebergMWM. Wendeberg
- J. M. RichterJRJ. M. Richter
- M. RotheMRM. Rothe
- W. A. BrandWBW. A. Brand
Preprint
- 13 September 2012
- preprint
- Published by Copernicus GmbH in EGUsphere
Abstract
The need for a unifying scale anchor for isotopes of CO2 in air was brought to light at the WMO CO2 Experts Meeting in Tokyo 2001. During discussions about persistent discrepancies in isotope measurements between the worlds leading laboratories it was concluded that a unifying scale anchor for VPDB of CO2 in air was desperately needed. Now, 10 yr later, the 2011 CO2-Experts-Meeting in Wellington has decided that the Jena Reference Air Set or JRAS is recommended as official scale anchor for isotope measurements of CO2 in air. The JRAS gases consist of reference CO2 mixed into CO2 free air. To safeguard both stability and longevity of the CO2, it is directly generated from two solid reference calcites. That the reference CO2 is supplied in air is unique to JRAS. This is made to ensure that any measurement bias arising from the extraction procedure is eliminated. As every lab has its own procedure for extracting the CO2 this is of paramount importance if the local scales are to be unified. For a period of four years, JRAS has been evaluated through the IMECC program, which made it possible to distribute sets of JRAS gases to 11 laboratories worldwide. A summary of the results is reported here along with a description of the production and maintenance of the JRAS scale anchors.Keywords
All Related Versions
- Published version: Atmospheric Measurement Techniques, 6 (3), 817.
This publication has 10 references indexed in Scilit:
- δ 18 O anchoring to VPDB: calcite digestion with 18 O‐adjusted ortho ‐phosphoric acidRapid Communications in Mass Spectrometry, 2011
- Correction for the 17O interference in δ(13C) measurements when analyzing CO2 with stable isotope mass spectrometry (IUPAC Technical Report)Pure and Applied Chemistry, 2010
- How well do we know VPDB? Variability of δ 13 C and δ 18 O in CO 2 generated from NBS19‐calciteRapid Communications in Mass Spectrometry, 2009
- Calcite‐CO 2 mixed into CO 2 ‐free air: a new CO 2 ‐in‐air stable isotope reference material for the VPDB scaleRapid Communications in Mass Spectrometry, 2005
- The effect of N 2 O on the isotopic composition of air‐CO 2 samplesRapid Communications in Mass Spectrometry, 2004
- N 2 O influence on isotopic measurements of atmospheric CO 2Rapid Communications in Mass Spectrometry, 2004
- On the 17 O correction for CO 2 mass spectrometric isotopic analysisRapid Communications in Mass Spectrometry, 2003
- Isotopic metrology of carbon dioxide. II. Effects of ion source materials, conductance, emission, and accelerating voltage on dual‐inlet cross contaminationRapid Communications in Mass Spectrometry, 2003
- Isotopic metrology of carbon dioxide. I. Interlaboratory comparison and empirical modeling of inlet equilibration time, inlet pressure, and ion source conductanceRapid Communications in Mass Spectrometry, 2003
- Cross contamination in dual inlet isotope ratio mass spectrometersInternational Journal of Mass Spectrometry, 2000