Intraoperative Invasive Blood Pressure Monitoring in Flap-Based Breast Reconstruction: Does It Change Outcomes?
Open Access
- 21 January 2021
- journal article
- research article
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery - Global Open
- Vol. 9 (1) , e3284
Abstract
Background: Despite the lack of guidelines regarding the use of intra-arterial lines in postmastectomy breast reconstruction (PMBR), they continue to be used in this setting. In this study of patients undergoing PMBR, we aimed to (1) identify factors associated with intra-arterial line placement, (2) analyze the correlation between intra-arterial monitoring and noninvasive blood pressure (NIBP) monitoring, and (3) investigate whether hemodynamic management differs significantly between patients undergoing intra-arterial blood pressure monitoring versus NIBP. Methods: All patients undergoing flap-based PMBR between 2017 and 2019 were retrospectively reviewed. Patients were pair-matched based on flap donor site, BMI, and age to identify factors associated with intra-arterial line placement. Methods described by Bland and Altman1 were utilized to determine agreement between intra-arterial line measurements and NIBP. Results: Thirty-two patients were included with 16 patients in the intra-arterial line group and 16 in the NIBP group. None of the factors studied were significantly related to the likelihood of intra-arterial line placement. Agreement analysis demonstrated that mean arterial pressures calculated from intra-arterial line readings were as much as 23 points lower or 12 points higher than those from NIBP. Bias calculations with this extent of difference suggest poor correlation between intra-arterial line readings and NIBP. There was no difference between groups in rate of administration of blood-pressure altering medications (hypertensive: n = 3, 18.8%, P = 1.000; hypotensive: n = 7, 3.8%, P = 1.000). Conclusion: Our findings highlight the need for more definitive guidance regarding the use of intra-arterial monitoring in patients undergoing PMBR.Keywords
This publication has 16 references indexed in Scilit:
- The accuracy of blood pressure measured by arterial line and non-invasive cuff in critically ill childrenCritical Care, 2016
- Surgical and Patient Risk Factors for Severe Arterial Line Complications in AdultsAnesthesiology, 2016
- Association Between Arterial Catheter Use and Hospital Mortality in Intensive Care UnitsJAMA Internal Medicine, 2014
- Continuous Monitoring in an Inpatient Medical-Surgical Unit: A Controlled Clinical TrialThe American Journal of Medicine, 2014
- Invasive and Concomitant Noninvasive Intraoperative Blood Pressure MonitoringAnesthesiology, 2011
- Recommendations for Blood Pressure Measurement in Humans and Experimental AnimalsHypertension, 2005
- Reliability of Allen’s test in selection of patients for radial artery harvestThe Annals of Thoracic Surgery, 2000
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- On the Safety of Radial Artery CannulationAnesthesiology, 1983
- Wrist Circumference Predicts the Risk of Radial-arterial Occlusion after CannulationAnesthesiology, 1978