Active-Arm Bridge with Two-Channel DC Voltage Source for Comparison of High-Resistance Standards in 1:1 Ratio
Open Access
Abstract
In this paper, a guarded active-arm bridge for high-resistance standards with programmable two-channel source of DC voltage is described. Both channels of this source are controlled from a common reference voltage. This ensures a high stability of the voltage ratio of both source channels. The presented results of tests of this source show that its use in the active bridge is more advantageous than the use of the two independent DC voltage sources. The bridge allows high accuracy in the comparison of the high-resistance standards in 1:1 ratio. The current state of knowledge about active-arm bridges is presented, the basics of the bridge operation are given, the two-channel DC voltage source used in the bridge and its test results are described, the measurement process that does not require transposition of the compared resistance standards is described, sample measurement results, and a plan for further work are given. The bridge is used in the resistance standard calibration system at the Central Office of Measures (GUM), Poland, in the range from 100 MΩ to 100 TΩ.Keywords
Funding Information
- Minister of Science and Higher Education (PM/SP/0014/2021/1)
This publication has 15 references indexed in Scilit:
- Double path system for resistance unit transfer from QHR primary standard to 100 TΩ standards2016
- Experiences With a Two-Terminal-Pair Digital Impedance BridgeIEEE Transactions on Instrumentation and Measurement, 2015
- High value resistance comparison using modified Wheatstone bridge based on current detectionMeasurement, 2013
- Resistance Scaling From 10 ${\rm k}\Omega$ Up to 100 ${\rm T}\Omega$ With New Designs of Hamon Transfer DevicesIEEE Transactions on Instrumentation and Measurement, 2013
- Automated High-Ohmic Resistance Bridge With Voltage and Current Null DetectionIEEE Transactions on Instrumentation and Measurement, 2013
- Evaluation of Two Alternative Methods to Calibrate Ultrahigh Value Resistors at INRIMIEEE Transactions on Instrumentation and Measurement, 2010
- Analysis of a dual-balance high-resistance bridge at 10 T/spl Omega/IEEE Transactions on Instrumentation and Measurement, 2001
- Automated guarded bridge for calibration of multimegohm standard resistors from 10 MΩ to 1 TΩIEEE Transactions on Instrumentation and Measurement, 1997
- A 25-bit reference resistive voltage dividerIEEE Transactions on Instrumentation and Measurement, 1987
- A new technique for the automatic measurement of high value resistorsJournal of Physics E: Scientific Instruments, 1987