Prevention of Cerebrospinal Fistulae and Reduction of Epidural Scar with New Surgical Hemostat Device in a Porcine Laminectomy Model
Authors:
- Jill Soble-SmithJSJill Soble-Smith
- Noël PowersNPNoël Powers
- Patricia A. NelsonPNPatricia A. Nelson
- 1 October 2003
- journal article
- research article
- Published by Wolters Kluwer Health in Spine
- Vol. 28 (19) , 2298-2303
Abstract
In a porcine laminectomy model, a standard dural/arachnoid incision was made and tested for cerebrospinal fluid leak after material application. Sites were graded for scar formation and healing response at 3 weeks. This study compares effectiveness of CoStasis, Tissucol, and suture for prevention of cerebrospinal fluid leaks and epidural scar formation after spinal dural incisions. Cerebrospinal fluid leaks following cranial and spinal surgery are potentially serious complications. Epidural scar formation is exacerbated by improper control of hemostasis. A hemostatic agent with dural sealant properties may be advantageous. Total laminectomy was performed at three levels in seven pigs. At each level, a uniform 1.5 cm incision was made in the dura and arachnoid. A single suture was placed to approximate the edges and sites were treated with one of three methods: CoStasis, Tissucol, or no treatment. At sacrifice, 3 weeks later, epidural scar was graded, pressure testing of some sites was done, and tissue for histologic sections was harvested. CoStasis and Tissucol produced immediate dural sealing when the valsalva maneuver was applied. One suture-only site leaked. At sacrifice, all sites were sealed. CoStasis and Tissucol had less scar formation than control sites. Pressure testing results were similar at CoStasis and Tissucol sites. CoStasis and Tissucol have comparable effectiveness in sealing CSF leaks immediately and at 3 weeks after complete laminectomy. CoStasis demonstrated comparable performance to Tissucol with less epidural scar formation than primary suture alone.Keywords
This publication has 29 references indexed in Scilit:
- A novel collagen-based composite offers effective hemostasis for multiple surgical indications: Results of a randomized controlled trialSurgery, 2001
- Effective Control of Hepatic Bleeding With a Novel Collagen-Based Composite Combined With Autologous PlasmaArchives of Surgery, 2000
- Costasis® Provides Superior Control of Diffuse Bleeding at Muscle-Flap Donor Sites, Compared to Manual CompressionJournal of Reconstructive Microsurgery, 2000
- Prevention of subdural fluid collections following transcortical intraventricular and/or paraventricular procedures by using fibrin adhesiveJournal of Neurosurgery, 2000
- A sprayable hemostat containing fibrillar collagen, bovine thrombin, and autologous plasmaThe Annals of Thoracic Surgery, 1999
- The Use of Gore-Tex Membrane for Adhesion Prevention in Tethered Spinal Cord Surgery: Technical Case ReportsNeurosurgery, 1999
- The prevention of peridural adhesions: A comparative long-term histomorphometric study using a biodegradable barrier and a fat graftThe Journal of Bone and Joint Surgery. British volume, 1998
- ADCON®-L SymposiumEuropean Spine Journal, 1996
- Role of peridural fibrosis in the failed back: a reviewEuropean Spine Journal, 1996
- Association Between Peridural Scar and Recurrent Radicular Pain After Lumbar Discectomy: Magnetic Resonance EvaluationNeurosurgery, 1996