Quantification of cortisol in human eccrine sweat by liquid chromatography – tandem mass spectrometry
Open Access
- 3 February 2016
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 141 (6) , 2053-2060
Abstract
Cortisol has long been recognized as the “stress biomarker” in evaluating stress related disorders. Plasma, urine or saliva are the current source for cortisol analysis. The sampling of these biofluids is either invasive or has reliability problems that could lead to inaccurate results. Sweat has drawn increasing attention as a promising source for non-invasive stress analysis. A sensitive HPLC-MS/MS method was developed for the quantitation of cortisol ((11β)-11,17,21-trihydroxypregn-4-ene-3,20-dione) in human eccrine sweat. At least one unknown isomer that has previously not been reported and could potentially interfere with quantification was separated from cortisol with mixed mode RP HPLC. Detection of cortisol was carried out using atmospheric pressure chemical ionization (APCI) and selected reaction monitoring (SRM) in positive ion mode, using cortisol-9,11,12,12-D4 as internal standard. LOD and LOQ were estimated to be 0.04 ng ml−1 and 0.1 ng ml−1, respectively. Linear range of 0.10–25.00 ng ml−1 was obtained. Intraday precision (2.5%–9.7%) and accuracy (0.5%–2.1%), interday precision (12.3%–18.7%) and accuracy (7.1%–15.1%) were achieved. This method has been successfully applied to the cortisol analysis of human eccrine sweat samples. This is the first demonstration that HPLC-MS/MS can be used for the sensitive and highly specific determination of cortisol in human eccrine sweat in the presence of at least one isomer that has similar hydrophobicity as cortisol. This study demonstrated that human eccrine sweat could be used as a promising source for non-invasive assessment of stress biomarkers such as cortisol and other steroid hormones.Keywords
Funding Information
- Air Force Research Laboratory (FA8650-13-2-7311)
This publication has 33 references indexed in Scilit:
- Usefulness of salivary cortisol in the diagnosis of hypercortisolism: comparison with serum and urinary cortisolEuropean Journal of Endocrinology, 2013
- Simultaneous determination of testosterone, cortisol, and dehydroepiandrosterone in saliva by stable isotope dilution on-line in-tube solid-phase microextraction coupled with liquid chromatography–tandem mass spectrometryAnalytical and Bioanalytical Chemistry, 2012
- Glucocorticoid regulation of inflammation and its functional correlates: from HPA axis to glucocorticoid receptor dysfunctionAnnals of the New York Academy of Sciences, 2012
- Development of a Sensitive Microarray Immunoassay for the Quantitative Analysis of Neuropeptide YAnalytical Chemistry, 2012
- A realtime and continuous assessment of cortisol in ISF using electrochemical impedance spectroscopySensors and Actuators A: Physical, 2011
- Gas chromatography/mass spectrometry (GC/MS) remains a pre-eminent discovery tool in clinical steroid investigations even in the era of fast liquid chromatography tandem mass spectrometry (LC/MS/MS)The Journal of Steroid Biochemistry and Molecular Biology, 2010
- A short history of sweat gland biologyInternational Journal of Cosmetic Science, 2007
- Measurement of cytokines in sweat patches and plasma in healthy women: Validation in a controlled studyJournal of Immunological Methods, 2006
- Capillary Electrophoresis-Based Immunoassay for Cortisol in SerumAnalytical Chemistry, 1995
- Determination of cortisol in human plasma by stable isotope dilution mass spectrometryJournal of Mass Spectrometry, 1988