A Possible, Non-Invasive Method of Measuring Dynamic Lung Compliance in Patients with Interstitial Lung Disease Using Photoplethysmography
Authors:
- 25 August 2021
- journal article
- research article
- Published by Medical Association of Nippon Medical School in Journal of Nippon Medical School
- Vol. 88 (4) , 326-334
Abstract
Background: Measuring lung compliance is useful for evaluating progression of interstitial lung disease (ILD), because reduced lung compliance due to fibrosis progression is the main cause of decreased vital capacity. However, because insertion of a balloon into the esophagus is invasive, lung compliance is rarely measured. A recently developed method uses fingertip photoplethysmography to estimate intra-thoracic pressure. This method non-invasively measures lung dynamic compliance (Cdyn) by simulta-neously measuring tidal volume. We evaluated the efficacy of this method in assessing ILD. Methods: This single-center, cross-sectional, observational study evaluated the efficacy of this method in patients with ILD and healthy controls. The primary outcome was estimated Cdyn (eCdyn), as deter-mined with this method. We also evaluated baseline characteristics that are potential confounding fac-tors for eCdyn. Results: Median eCdyn was significantly lower in the ILD group (n = 14) than in the control group (n = 49) (0.122 vs. 0.183; P = 0.011). In univariate regression analysis, eCdyn was significantly correlated with height, weight, forced vital capacity, forced expiratory volume in 1 second, diffusing capacity for carbon monoxide, and usual interstitial pneumonia. In multivariate regression analysis, weight (beta = 0.49, P = 0.011) and usual interstitial pneumonia (beta = 0.52, P = 0.007) were significantly correlated with eCdyn. Conclusions: Using photoplethysmography, we noted a significant reduction in Cdyn in patients with ILD. This novel non-invasive method is a promising tool for evaluating fibrosis progression in ILD.Keywords
This publication has 24 references indexed in Scilit:
- An Official ATS/ERS/JRS/ALAT Statement: Idiopathic Pulmonary Fibrosis: Evidence-based Guidelines for Diagnosis and ManagementAmerican Journal of Respiratory and Critical Care Medicine, 2011
- Reference values for dynamic and static pulmonary compliance in menRespiratory Medicine, 2007
- Flow Velocity Paradoxus and Pulsus Paradoxus in Obstructive Sleep Apnea SyndromeChest, 1993
- Leftward Shift of the Interventricular Septum and Pulsus Paradoxus in Obstructive Sleep Apnea SyndromeChest, 1991
- Echocardiographic study of the paradoxical arterial pulse in chronic obstructive lung disease.Circulation, 1980
- Morphologic-physiologic correlates of the severity of fibrosis and degree of cellularity in idiopathic pulmonary fibrosis.Journal of Clinical Investigation, 1979
- PULSUS PARADOXUS AS A VALUABLE SIGN INDICATING SEVERITY OF ASTHMAThe Lancet, 1973
- Direct-Writing Recorder of the Flow-Volume Curve and Its Clinical ApplicationChest, 1972
- Frequency dependence of compliance as a test for obstruction in the small airwaysJournal of Clinical Investigation, 1969
- Pulsus paradoxus.Journal of Clinical Investigation, 1965