Abstract
Direct resolution of (±)‐ephedrine and atropine into their enantiomers was achieved by normal‐phase thin layer chromatography on silica gel plates impregnated with optically pure L‐tartaric acid and L‐histidine, respectively, as chiral selectors. The mobile phases enabling successful resolution were different combinations of acetonitrile–methanol–water. The spots were detected with iodine vapours and the detection limits were 2 and 6 µg, respectively, in terms of the racemate. The effects of concentration of the impregnating reagent, temperature and pH on resolution have been studied. Copyright © 2001 John Wiley & Sons, Ltd.
Funding Information
  • All India Council for Technical Education (8017/RDII/PHA/98)

This publication has 25 references indexed in Scilit: