Validation of the Updated GloboDiet Version by Protein and Potassium Intake for the German National Nutrition Monitoring
Open Access
Abstract
(1) Background: The German version of GloboDiet, a software for a computer-based assessment of 24 h recalls, was intensively updated. Therefore, validation is required prior to its use in the upcoming data collection within the German National Nutrition Monitoring. (2) Methods: For this purpose, the cross-sectional ErNst study with 109 participants (57 women and 52 men) was conducted. The study provided data on 24 h GloboDiet recalls and 24 h urine samples from the same day. Protein and potassium intake, known as eligible validation markers, were compared to the measured excretion in urine. To assess the agreement between intake and excretion, the following statistical methods were used: Wilcoxon rank tests, confidence intervals, Spearman correlations, and Bland–Altman plots. (3) Results: Overall, the updated German GloboDiet version showed valid estimates of protein intake. Regarding potassium, results were ambiguous and differed depending on the statistical method applied. While the Bland–Altman plot showed a good agreement between 24 h recalls and urine samples for potassium, the correlation was weak, suggesting that 24 h recalls may underestimate true intake. (4) Conclusions: Despite the partly ambiguous results, the updated GloboDiet version linked to the current German Nutrient Database provides valid estimates of nutrient intake.Keywords
Funding Information
- Federal Ministry of Food and Agriculture
This publication has 50 references indexed in Scilit:
- Bias in protein and potassium intake collected with 24-h recalls (EPIC-Soft) is rather comparable across European populationsEuropean Journal of Nutrition, 2011
- The European Food Consumption Validation Project: conclusions and recommendationsEuropean Journal of Clinical Nutrition, 2011
- The standardized computerized 24-h dietary recall method EPIC-Soft adapted for pan-European dietary monitoringEuropean Journal of Clinical Nutrition, 2011
- Two non-consecutive 24 h recalls using EPIC-Soft software are sufficiently valid for comparing protein and potassium intake between five European centres – results from the European Food Consumption Validation (EFCOVAL) studyBritish Journal of Nutrition, 2010
- Estimate of total salt intake in two regions of Belgium through analysis of sodium in 24-h urine samplesEuropean Journal of Clinical Nutrition, 2010
- Comparison of telephone vs face-to-face interviews in the assessment of dietary intake by the 24 h recall EPIC SOFT program—the Norwegian calibration studyEuropean Journal of Clinical Nutrition, 2003
- Critical evaluation of energy intake using the Goldberg cut-off for energy intake:basal metabolic rate. A practical guide to its calculation, use and limitationsInternational Journal of Obesity, 2000
- Validation of weighed records and other methods of dietary assessment using the 24 h urine nitrogen technique and other biological markersBritish Journal of Nutrition, 1995
- THE DOMINANCE OF SALT IN MANUFACTURED FOOD IN THE SODIUM INTAKE OF AFFLUENT SOCIETIESThe Lancet, 1987
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986