The Relationship Between Kiritsu-Meijin-Derived Autonomic Function Parameters and Visual-Field Defects in Eyes with Open-Angle Glaucoma
Authors:
- 19 July 2023
- journal article
- research article
- Published by Taylor & Francis in Current Eye Research
- Vol. 48 (11) , 1006-1013
Abstract
PurposeThis retrospective cross-sectional study aimed to investigate the association between autonomic parameters measured using the Kiritsu-Meijin device and visual-field defects in patients with open-angle glaucoma.MethodsA total of 79 eyes of 42 patients with open-angle glaucoma were enrolled in this study. Kiritsu-Meijin testing comprised three phases: sitting, standing, and sitting again (2 min, 2 min, and 1 min, respectively). Continuous electrocardiograms were recorded for five minutes. Autonomic parameters were extracted from the resulting data and analyzed, including activity, balance, reaction, switchover, and recovery; these are five representative parameters derived from Kiritsu-Meijin testing. Correlations between these parameters and mean deviation from Humphrey visual field testing were determined. Additionally, we used a linear mixed-effects model to observe sectoral differences in the relationship between total deviation and the Kiritsu-Meijin parameters. In this study, we focused on superior, central, and inferior total deviations.ResultsSignificant positive correlations were observed between activity, balance, and recovery and mean deviation values (& beta; = 0.29-0.38, p < .05). The & beta; value between activity and inferior total deviation was higher than that between activity and superior total deviation (& beta; = 0.22, p < .05). Balance did not show any sectoral differences (p > .05). Recovery was more strongly associated with central to inferior total deviation than superior total deviation (& beta; = 0.17-0.25, p < .05).ConclusionOur findings suggest that in patients with open-angle glaucoma, lower activity and recovery are associated with more severe central and/or inferior visual field defects in the superior quadrant. These results imply that measurements of autonomic function made with the Kiritsu-Meijin device may have clinical utility in the management of glaucoma.Keywords
Funding Information
- COI-NEXT (JPMJPF2201)
This publication has 40 references indexed in Scilit:
- Cardiac autonomic dysfunction in patients with normal tension glaucoma: 24-h heart rate and blood pressure variability analysisBritish Journal of Ophthalmology, 2012
- Autonomic control of the eye and the irisAutonomic Neuroscience, 2011
- Vagal Stimulation for Heart Diseases: From Animals to Men - An Example of Translational Cardiology -Circulation Journal, 2011
- Heart rate variability as a measure of cardiac autonomic function in anorexia nervosa: A review of the literatureEuropean Eating Disorders Review, 2010
- Influence of the Extent of Myopia on the Progression of Normal-Tension GlaucomaAmerican Journal of Ophthalmology, 2010
- The Sympathetic Nervous System in Heart FailureJACC, 2009
- Sympathetic Nervous System Activation in Human Heart FailureJACC, 2009
- The prevalence of primary open-angle glaucoma in Japanese*1The Tajimi StudyOphthalmology, 2004
- Mapping the visual field to the optic disc in normal tension glaucoma eyes11The authors have no proprietary interest in the development or marketing of any product or instrument mentioned in this article.Ophthalmology, 2000
- Accuracy of assessment of cardiac vagal tone by heart rate variability in normal subjectsThe American Journal of Cardiology, 1991