Reliability of 2 Protocols for Assessing Pressure Pain Threshold in Healthy Young Adults
- 1 May 2015
- journal article
- Published by National University of Health Sciences in Journal of Manipulative and Physiological Therapeutics
- Vol. 38 (4) , 282-287
Abstract
The purposes of this study were to determine whether there were differences in mean values or reliability for 2 frequently used protocols for pressure pain threshold (PPT) and to calculate how large a difference in PPT is necessary to be 95% confident that a real change has occurred. Thirteen participants (8 females) aged 22.3 (±2.3) years from a university community were included. Two testers evaluated participants using 2 protocols, in which PPT was measured 3 times at 8 different body locations. The "cluster protocol" consisted of 3 successive measurements at each location with a 30-second rest between each measurement. The "circuit protocol" consisted of 1 measurement taken at each anatomical location until "the circuit" was complete and then repeated a total of 3 times. A 2-way analysis of variance did not reveal significant differences between protocols at any body location (P = .46-.98). Intertester reliability was good to excellent for all locations (intraclass correlation coefficient, 0.84-0.96), and limits of agreement ranged from 108 to 223 kPa. Either the cluster or circuit protocol can be used to measure PPT in clinical or research setting. A difference of 160 kPa is considered sufficient to indicate a real difference between repeated measures of PPT regardless of protocol used for testing.Keywords
This publication has 29 references indexed in Scilit:
- Analysis of deep tissue hypersensitivity to pressure pain in professional pianists with insidious mechanical neck painBMC Musculoskeletal Disorders, 2011
- Pressure pain sensitivity maps of the neck-shoulder and the low back regions in men and womenBMC Musculoskeletal Disorders, 2010
- Mobilisation with movement and exercise, corticosteroid injection, or wait and see for tennis elbow: randomised trialBMJ, 2006
- PRESSURE ALGOMETRY IN HEALTHY SUBJECTS: INTER-EXAMINER VARIABILITYJournal of Rehabilitation Medicine, 1998
- Reliability, Validity, Reproducibility of Algometry in Diagnosis of Active and Latent Tender Spots and Trigger PointsJournal of Musculoskeletal Pain, 1998
- Algometry in Diagnosis of Musculoskeletal Pain and Evaluation of Treatment Outcome: An UpdateJournal of Musculoskeletal Pain, 1998
- Statistical Methods For Assessing Measurement Error (Reliability) in Variables Relevant to Sports MedicineSports Medicine, 1998
- Pressure algometry over normal muscles. Standard values, validity and reproducibility of pressure thresholdPain, 1987
- Pressure-pain threshold in human temporal region. Evaluation of a new pressure algometerPain, 1986
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986