Abstract
Due to the improper corrosion protection of and under the ground anchor head, corrosion was a big problem for tens of thousands service of ground anchors in Taiwan. Humid weather and abundant groundwater conditions are also the contributing factors. Two major steps have been taken to prevent the current anchor condition from getting worse; and to prevent such a corrosion problem from happening in the new anchors. For the existing service anchors, cement grout was injected from outside to the void beneath anchor head to prevent further exposure of strands to the water and air. For the new anchors, corrosion protection measures to all components of the ground anchor are carefully applied. Special attention is paid to the free anchor end right under the anchor head and the anchor head itself. To make sure the void is a fully filled up of cement grout, a specially designed bearing plate assembly is used to facilitate the process to fill up the annular space outside the plastic sheath and under the anchor head. The effectiveness of filling up the voids under the anchor head can be visually inspected from the bearing plate assembly. An electrical resistance test took on the complete anchors confirmed the integrity of corrosion protection measures.

This publication has 1 reference indexed in Scilit: