Abstract
The assessment of VOC emission rates and sorption coefficients was performed for ten surfaces present within a classroom, using field and laboratory emission cells (FLEC) coupled to online and offline VOC quantification techniques. 21 identified VOCs were emitted by the different surfaces. VOC emission rates measured using PTR‐ToF‐MS were compared to gas chromatographic measurements. The results showed that the two methods are complementary to one another. Sorption parameters were also successfully measured for a mixture of 14 VOCs within a few hours (< 17 hours/surface). A study of the spatial and temporal variability of the measured parameters was also carried out on the two surfaces that presented the most potential for interaction with VOCs, accounting for the largest surface areas within the room. The dataset of emission rates and sorption parameters were used in the INCA‐Indoor model to predict indoor air concentrations of VOCs that are compared to experimental values measured in the room. Modeling results showed that sorption processes had a limited effect on indoor concentrations of VOCs for these field campaigns. Modeled daily profiles show good agreement with the experimental observations for VOCs such as toluene (indoor source) and xylenes (outdoor source) but underestimate concentrations of methanol (both indoor and outdoor sources).
Funding Information
  • French Environment and Energy Management Agency ADEME (Agence de I'Environment et de la Maîtrise de I'Energie)
  • French ANR agency

This publication has 52 references indexed in Scilit: