Measurement of high energy x-ray beam penumbra with Gafchromic™ EBT radiochromic film
Authors:
- 25 July 2006
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 33 (8) , 2912-2914
Abstract
High energy x-ray beam penumbra are measured using Gafchromic EBT film. Gafchromic EBT, due to its limited energy dependence and high spatial resolution provide a high level of accuracy for dose assessment in penumbral regions. The spatial resolution of film detector systems is normally limited by the scanning resolution of the densitometer. Penumbral widths (80%/20%) measured at Dmax were found to be 2.8, 3.0, 3.2, and 3.4 mm (+/- 0.2 mm) using 5, 10, 20, and 30 cm square field sizes, respectively, for a 6 MV linear accelerator produced x-ray beam. This is compared to 3.2 mm +/- 0.2 mm (Kodak EDR2) and 3.6 mm +/- 0.2 mm (Kodak X-Omat V) at 10 cm x 10 cm measured using radiographic film. Using a zero volume extrapolation technique for ionization chamber measurements, the 10 cm X 10 cm field penumbra at Dmax was measured to be 3.1 mm, a close match to Gafchromic EBT results. Penumbral measurements can also be made at other depths, including the surface, as the film does not suffer significantly from dosimetric variations caused by changing x-ray energy spectra. Gafchromic EBT film provides an adequate measure of penumbral dose for high energy x-ray beams.Keywords
Funding Information
- Research Grants Council of HKSAR, China (CityU100404)
This publication has 16 references indexed in Scilit:
- Characterization and real‐time optical measurements of the ionizing radiation dose response for a new radiochromic mediumMedical Physics, 2005
- The use of film dosimetry of the penumbra region to improve the accuracy of intensity modulated radiotherapyMedical Physics, 2004
- Experimental energy response verification of XR type T radiochromic filmPhysics in Medicine & Biology, 2004
- Rounded end multi-leaf penumbral measurements with radiochromic filmPhysics in Medicine & Biology, 2003
- Characteristics of sensitometric curves of radiographic filmsMedical Physics, 2003
- Rapid radiographic film calibration for IMRT verification using automated MLC fieldsMedical Physics, 2002
- Dosimetric performance of an enhanced dose range radiographic film for intensity‐modulated radiation therapy quality assuranceMedical Physics, 2002
- A dosimetric comparison of various multileaf collimatorsPhysics in Medicine & Biology, 2002
- Spatial resolution of a stacked radiochromic film dosimeterRadiotherapy and Oncology, 2001
- Dose response of various radiation detectors to synchrotron radiationPhysics in Medicine & Biology, 1998