Influence of timing jitter on quadrature charge sampling
Authors:
- 2 August 2007
- journal article
- Published by Institution of Engineering and Technology (IET) in IET Communications
- Vol. 1 (4) , 705-710
Abstract
The influence of timing jitter on quadrature charge sampling for a direct conversion receiver has been evaluated. In contrast to voltage sampling, the charge sampling mixer integrates the signal current instead of tracking the signal voltage. The charge sampling mixer has been applied to RF direct sampling in wireless receivers. The influence of timing jitter on charge sampling has been analysed in some literatures. However, in wireless receivers, quadrature sampling is required in order to demodulate I-phase and Q-phase signals. Different from charge sampling, timing jitter causes crosstalk between these signals. The influence of timing jitter on quadrature sampling is investigated.Keywords
This publication has 5 references indexed in Scilit:
- All-digital TX frequency synthesizer and discrete-time receiver for Bluetooth radio in 130-nm CMOSIEEE Journal of Solid-State Circuits, 2004
- A discrete-time Bluetooth receiver in a 0.13μm digital CMOS process2004
- A first multigigahertz digitally controlled oscillator for wireless applicationsIEEE Transactions on Microwave Theory and Techniques, 2003
- Performance trends for analog to digital convertersIEEE Communications Magazine, 1999
- Jitter analysis of high-speed sampling systemsIEEE Journal of Solid-State Circuits, 1990