Magnetic field sensitivity at 7-T using dual-helmholtz transmit-only coil and 12-channel receive-only bended coil
Authors:
Abstract
The purpose of this study was to combine a dual-Helmholtz (DH) transmit (Tx)-only coil and 12-channel receive (Rx)-only bended phased array (PA) coil to improve the magnetic flux (|B1 |) sensitivity in the superior-to-inferior (S-I) direction during human brain magnetic resonance imaging (MRI) at 7-T. The proposed coil combination was primarily implemented by electromagnetic (EM) simulation and compared with the 16-leg birdcage coil and 8-channel PA coil, which are generally used for the Tx- and Rx-only modes, respectively. The optimal coil combinations for the proposed structure were determined by |B1 | field calculations using the |BT (+) | and |BR (-) | fields, which are respectively the transmit and receive components of the |B1 | field. The coil performance was then evaluated by a bench test and 7-T MRI experiment. The results of the computational calculations indicated that the |BT (+) | field of the DH coil was distributed similarly to that of the 16-leg birdcage coil despite the fewer conducting legs of the former. However, the 12-channel Rx-only bended PA coil had clearly higher |BR (-) | profiles compared to the 8-channel PA coil. The results of the 7-T in vivo experiment showed that the proposed combination of the DH Tx-only coil and 12-channel Rx-only bended PA coil had better |B1 | field homogeneity in the sagittal slice as well as higher |B1 | field sensitivity during human brain MRI compared to an 8-channel Rx-only PA coil. SCANNING 9999:1-10, 2015. © 2015 Wiley Periodicals, Inc.Keywords
Funding Information
- National Research Foundation of Korea
- Ministry of Education, Science and Technology of the Republic of Korea (NRF-2014M3C7033998)
- Korea Health Technology R&D Project through the Korea Health Industry Development Institute (KHIDI)
- Ministry of Health and Welfare of the Republic of Korea (HR14C-0002-010014)
This publication has 21 references indexed in Scilit:
- A fusion PET–MRI system with a high‐resolution research tomograph‐PET and ultra‐high field 7.0 T‐MRI for the molecular‐genetic imaging of the brainProteomics, 2008
- New brain atlas—Mapping the human brain in vivo with 7.0 T MRI and comparison with postmortem histology: Will these images change modern medicine?International Journal of Imaging Systems and Technology, 2008
- A hybrid PET‐MRI: An integrated molecular‐genetic imaging system with HRRT‐PET and 7.0‐T MRIInternational Journal of Imaging Systems and Technology, 2007
- Central brightening due to constructive interference with, without, and despite dielectric resonanceJournal of Magnetic Resonance Imaging, 2005
- Evaluation of internal MRI coils using ultimate intrinsic SNRMagnetic Resonance in Medicine, 2004
- Signal‐to‐noise ratio and parallel imaging performance of a 16‐channel receive‐only brain coil array at 3.0 TeslaMagnetic Resonance in Medicine, 2003
- Theoretical and experimental evaluation of detached endcaps for 3 T birdcage coilsMagnetic Resonance in Medicine, 2003
- Radio frequency magnetic field mapping of a 3 Tesla birdcage coil: Experimental and theoretical dependence on sample propertiesMagnetic Resonance in Medicine, 2001
- The intrinsic signal‐to‐noise ratio in NMR imagingMagnetic Resonance in Medicine, 1986
- Nonionizing electromagnetic wave effects in biological materials and systemsProceedings of the IEEE, 1972