EVO+ Implantable Collamer Lens KS-aquaPORT Location, Stability, and Impact on Quality of Vision and Life
- 1 March 2022
- journal article
- research article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 38 (3) , 177-183
Abstract
PURPOSE: To determine the longitudinal variation in the KS-aquaPORT central hole location of the phakic EVO+ Implantable Collamer Lens (ICL) (STAAR Surgical) and analyze its influence on visual performance, quality of vision (QoV), and quality of life (QoL). METHODS: A prospective study was performed including 36 patients who had EVO+ ICL implantation. The KS-aquaPORT central hole location (Cartesian and polar coordinates) was determined with respect to the pupil center and visual axis. The effect of time (6-month follow-up) on central hole location was analyzed using linear mixed models. The effect of the KS-aquaPORT location on visual performance, QoV, and QoL parameters was assessed with multivariate regression models. RESULTS: With respect to the visual axis, no significant changes in KS-aquaPORT location were found during follow-up. With respect to the pupil center, the X-coordinate and radius of KS-aquaPORT location showed modest, but significant ( P ≤ .05) differences between 1-week and 3-month postoperative visits, and between 1-week and 6-month visits. X-coordinate variation was significant ( P = .022) between 1-and 6-month visits. With respect to the visual axis, greater KS-aquaPORT decentration was associated with worse visual acuity (X-coordinate: P = .004; radius: P = .006), and inferior decentration with longer xenon-type glare photostress recovery time ( P = .021). With respect to the pupil center, a lower radius was associated with better QoV scores ( P ≤ .01) and temporal decentration produced higher ring-shaped dysphotopsia ( P = .007). CONCLUSIONS: EVO+ ICL KS-aquaPORT location appears to be clinically stable up to 6 months postoperatively. A central location of the EVO+ ICL KS-aquaPORT hole is preferred because it allows reduced perception of dysphotopic phenomena that can result in better QoV. [ J Refract Surg . 2022;38(3):177–183.]Keywords
This publication has 28 references indexed in Scilit:
- Measurement of Pupil Center Shift in Refractive Surgery Candidates With Caucasian Eyes Using Infrared PupillometryJournal of Refractive Surgery, 2014
- Comparative Study of 2 Types of Implantable Collamer Lenses, 1 With and 1 Without a Central Artificial HoleAmerican Journal of Ophthalmology, 2014
- Risk Factors Associated With Night Vision Disturbances After Phakic Intraocular Lens ImplantationAmerican Journal of Ophthalmology, 2014
- The Quality of Vision QuestionnaireOptometry and Vision Science, 2013
- Predictive factor and kappa angle analysis for visual satisfactions in patients with multifocal IOL implantationEye, 2011
- The Development of an Instrument to Measure Quality of Vision: The Quality of Vision (QoV) QuestionnaireInvestigative Ophthalmology & Visual Science, 2010
- Dissatisfaction after multifocal intraocular lens implantationJournal of Cataract & Refractive Surgery, 2009
- Eye dominance effects in feature searchVision Research, 2006
- Implantable contact lens for moderate to high myopiaJournal of Cataract & Refractive Surgery, 2003
- Optical Zone Centration in Keratorefractive SurgeryOphthalmology, 1993