ITER full model in MCNP for radiation safety demonstration
Preprint
- 20 March 2024
- preprint
- Published by Springer Nature in Research Square
Abstract
Development of nuclear fusion as a safe and virtually limitless power source receives growing attention in the context of looming energy crisis and climate change. ITER project stands as the flagship international project and advances steadily. Construction of the Tokamak Complex is nearly finished, and the assembly of core components has started in the site. In parallel, design is getting finalized and the safety case gets more concrete. Current approaches for radiation safety demonstration based in 3D nuclear analysis require sophisticated artifacts due to the consideration of separate MCNP models for the Tokamak and the rest of the facility, resulting in cumbersome studies and thus, debilitated conclusions. To improve this situation, we have built the first integral MCNP model of the ITER facility: the ITER full model. Accompanied by improvements to the D1SUNED code, we illustrate its computational practicality and pertinence in two meaningful simulations for ITER safety case. This work represents the culmination of a two-decades-long effort of ITER modelling seeking to demonstrate the radiation safety. Beyond supporting the remaining design tasks, this model represents a noticeable simplification in the approach to produce the corresponding 3D nuclear analysis. It improves the robustness of the first-of-a-kind ITER safety case.Keywords
All Related Versions
- Version 1, 2024-03-20, Research Square
- Published version: Nature Communications, 15 (1), 1.
This publication has 35 references indexed in Scilit:
- Development of radiation sources for nuclear analysis beyond ITER bio-shield: SRC-UNED codeComputer Physics Communications, 2022
- Radiation levels in the ITER tokamak complex during and after plasma operationFusion Engineering and Design, 2015
- Modelling and shielding analysis of the neutral beam injector ports in ITERFusion Engineering and Design, 2015
- Movement of active components in the shutdown dose rate analysis of the ITER neutral beam injectorsFusion Engineering and Design, 2015
- First neutronics analysis for ITER bio-shield equatorial port plugFusion Engineering and Design, 2012
- An easy to implement global variance reduction procedure for MCNPAnnals of Nuclear Energy, 2011
- Comparison of global variance reduction techniques for Monte Carlo radiation transport simulations of ITERFusion Engineering and Design, 2011
- CAD-based interface programs for fusion neutron transport simulationFusion Engineering and Design, 2009
- Use of McCad for the conversion of ITER CAD data to MCNP geometryFusion Engineering and Design, 2008
- Neutronic analysis of ITER neutral beam test bedFusion Engineering and Design, 2005