Near‐Thorough QT Study as Part of a First‐In‐Man Study
Authors:
- Marek MalikMMMarek Malik
- Katerina HnatkovaKHKaterina Hnatkova
- John FordJFJohn Ford
- David MadgeDMDavid Madge
- 1 October 2008
- journal article
- clinical trial
- Published by Wiley in The Journal of Clinical Pharmacology
- Vol. 48 (10) , 1146-1157
Abstract
Detailed electrocardiographic (ECG) support was provided to a first‐in‐man, single‐ascending‐dose study that included 6 cohorts of 8 male volunteers each. In each cohort, 6 and 2 subjects received active compound and placebo, respectively. Long‐term 12‐lead ECGs were obtained on baseline day −1, dosing day 1, and day 2. Automatic QT‐interval measurements were made at 63 time points (28 at baseline and 35 on treatment). Based on QT/RR distribution, 20% of measurements were visually verified. Baseline‐corrected time‐matched ΔQTc values were obtained at 35 postdose time points. Placebo subjects of all cohorts were pooled. When 2 cohorts of the lowest, middle, and highest doses were pooled (12 subjects per active treatment group), the spreads of placebo‐corrected ΔΔQTc values were within the regulatory requirements (single‐sided 95% confidence interval <1 0 milliseconds) at all time points. Thus, this ECG support of the first‐in‐man study provided data of regulatory acceptable accuracy at a small fraction of the cost of a full thorough QT study.Keywords
This publication has 22 references indexed in Scilit:
- Statistical Issues Including Design and Sample Size Calculation in Thorough QT/QTc StudiesJournal of Biopharmaceutical Statistics, 2008
- Concentration‐QT Relationships Play a Key Role in the Evaluation of Proarrhythmic Risk During Regulatory ReviewThe Journal of Clinical Pharmacology, 2008
- Detection of drug-induced proarrhythmia: Balancing preclinical and clinical studiesHeart Rhythm, 2005
- Sample Size, Power Calculations, and Their Implications for the Cost of Thorough Studies of Drug Induced QT Interval ProlongationPacing and Clinical Electrophysiology, 2004
- Comparing Methods of Measurement for Detecting Drug‐Induced Changes in the QT Interval: Implications for Thoroughly Conducted ECG StudiesAnnals of Noninvasive Electrocardiology, 2004
- Developments in ECG acquisition, preprocessing, parameter measurement, and recordingIEEE Engineering in Medicine and Biology Magazine, 1998
- Heart rate variability: Origins, methods, and interpretive caveatsPsychophysiology, 1997
- Heart Rate VariabilityCirculation, 1996
- Electrocardiogram baseline noise estimation and removal using cubic splines and state-space computation techniquesComputers and Biomedical Research, 1977
- Die Systolendauer im Elektrokardiogramm bei normalen Menschen und bei HerzkrankenActa Medica Scandinavica, 1920