Optimization of LC-Orbitrap-HRMS acquisition and MZmine 2 data processing for nontarget screening of environmental samples using design of experiments
- 7 October 2016
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 408 (28) , 7905-7915
Abstract
Abstract Liquid chromatography–high resolution mass spectrometry (LC-HRMS) is a well-established technique for nontarget screening of contaminants in complex environmental samples. Automatic peak detection is essential, but its performance has only rarely been assessed and optimized so far. With the aim to fill this gap, we used pristine water extracts spiked with 78 contaminants as a test case to evaluate and optimize chromatogram and spectral data processing. To assess whether data acquisition strategies have a significant impact on peak detection, three values of MS cycle time (CT) of an LTQ Orbitrap instrument were tested. Furthermore, the key parameter settings of the data processing software MZmine 2 were optimized to detect the maximum number of target peaks from the samples by the design of experiments (DoE) approach and compared to a manual evaluation. The results indicate that short CT significantly improves the quality of automatic peak detection, which means that full scan acquisition without additional MS2 experiments is suggested for nontarget screening. MZmine 2 detected 75–100 % of the peaks compared to manual peak detection at an intensity level of 105 in a validation dataset on both spiked and real water samples under optimal parameter settings. Finally, we provide an optimization workflow of MZmine 2 for LC-HRMS data processing that is applicable for environmental samples for nontarget screening. The results also show that the DoE approach is useful and effort-saving for optimizing data processing parameters. ᅟKeywords
Funding Information
- The European FP7 Collaborative Project SOLUTIONS (603437)
- The European Marie Curie Initial Training Network EDA-EMERGE (290100)
This publication has 27 references indexed in Scilit:
- Quantitative target and systematic non-target analysis of polar organic micro-pollutants along the river Rhine using high-resolution mass-spectrometry – Identification of unknown sources and compoundsWater Research, 2015
- Advancing towards universal screening for organic pollutants in watersJournal of Hazardous Materials, 2015
- Competitive fragmentation modeling of ESI-MS/MS spectra for putative metabolite identificationMetabolomics, 2014
- MET-COFEA: A Liquid Chromatography/Mass Spectrometry Data Processing Platform for Metabolite Compound Feature Extraction and AnnotationAnalytical Chemistry, 2014
- Identification of novel micropollutants in wastewater by a combination of suspect and nontarget screeningEnvironmental Pollution, 2014
- MZmine 2: Modular framework for processing, visualizing, and analyzing mass spectrometry-based molecular profile dataBMC Bioinformatics, 2010
- LC–high resolution MS in environmental analysis: from target screening to the identification of unknownsAnalytical and Bioanalytical Chemistry, 2010
- The Challenge of Micropollutants in Aquatic SystemsScience, 2006
- MZmine: toolbox for processing and visualization of mass spectrometry based molecular profile dataBioinformatics, 2006
- XCMS: Processing Mass Spectrometry Data for Metabolite Profiling Using Nonlinear Peak Alignment, Matching, and IdentificationAnalytical Chemistry, 2006