DiffUS: Differentiable Ultrasound Rendering from Volumetric Imaging
Preprint
Abstract
Intraoperative ultrasound imaging provides real-time guidance during numerous surgical procedures, but its interpretation is complicated by noise, artifacts, and poor alignment with high-resolution preoperative MRI/CT scans. To bridge the gap between reoperative planning and intraoperative guidance, we present DiffUS, a physics-based, differentiable ultrasound renderer that synthesizes realistic B-mode images from volumetric imaging. DiffUS first converts MRI 3D scans into acoustic impedance volumes using a machine learning approach. Next, we simulate ultrasound beam propagation using ray tracing with coupled reflection-transmission equations. DiffUS formulates wave propagation as a sparse linear system that captures multiple internal reflections. Finally, we reconstruct B-mode images via depth-resolved echo extraction across fan-shaped acquisition geometry, incorporating realistic artifacts including speckle noise and depth-dependent degradation. DiffUS is entirely implemented as differentiable tensor operations in PyTorch, enabling gradient-based optimization for downstream applications such as slice-to-volume registration and volumetric reconstruction. Evaluation on the ReMIND dataset demonstrates DiffUS's ability to generate anatomically accurate ultrasound images from brain MRI data.Keywords
All Related Versions
This publication has 15 references indexed in Scilit:
- Synthetic data accelerates the development of generalizable learning-based algorithms for X-ray image analysisNature Machine Intelligence, 2023
- SynthSeg: Segmentation of brain MRI scans of any contrast and resolution without retrainingMedical Image Analysis, 2023
- NeSVoR: Implicit Neural Representation for Slice-to-Volume Reconstruction in MRIIEEE Transactions on Medical Imaging, 2023
- Standardization of brain MR images across machines and protocols: bridging the gap for MRI-based radiomicsScientific Reports, 2020
- Deformable MRI-Ultrasound registration using correlation-based attribute matching for brain shift correction: Accuracy and generality in multi-site dataNeuroImage, 2019
- Measurement of bound and pore water T1relaxation times in cortical bone using three-dimensional ultrashort echo time cones sequencesMagnetic Resonance in Medicine, 2016
- Robust Super-Resolution Volume Reconstruction From Slice Acquisitions: Application to Fetal Brain MRIIEEE Transactions on Medical Imaging, 2010
- Automatic CT-ultrasound registration for diagnostic imaging and image-guided interventionMedical Image Analysis, 2008
- Basic physics of ultrasound imagingCritical Care Medicine, 2007
- The calibration of CT Hounsfield units for radiotherapy treatment planningPhysics in Medicine & Biology, 1996