Channelized Hotelling observers for the assessment of volumetric imaging data sets
- 20 May 2011
- journal article
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 28 (6) , 1145-1163
Abstract
Current clinical practice is rapidly moving in the direction of volumetric imaging. For two-dimensional (2D) images, task-based medical image quality is often assessed using numerical model observers. For three- dimensional (3D) images, however, these models have been little explored so far. In this work, first, two novel designs of a multislice channelized Hotelling observer (CHO) are proposed for the task of detecting 3D signals in 3D images. The novel designs are then compared and evaluated in a simulation study with five different CHO designs: a single-slice model, three multislice models, and a volumetric model. Four different random background statistics are considered, both Gaussian (noncorrelated and correlated Gaussian noise) and non-Gaussian (lumpy and clustered lumpy backgrounds). Overall, the results show that the volumetric model outperforms the others, while the disparity between the models decreases for greater complexity of the detection task. Among the multislice models, the second proposed CHO could most closely approach the volumetric model, whereas the first new CHO seems to be least affected by the number of training samples.Keywords
Funding Information
- Interdisciplinary Institute for BroadBand Technology (IBBT)
This publication has 40 references indexed in Scilit:
- A Practical, Automated Quality Assurance Method for Measuring Spatial Resolution in PETJournal of Nuclear Medicine, 2009
- Breast tomosynthesis and digital mammography: a comparison of breast cancer visibility and BIRADS classification in a population of cancers with subtle mammographic findingsEuropean Radiology, 2008
- PET versus SPECT: strengths, limitations and challengesNuclear Medicine Communications, 2008
- Validating the use of channels to estimate the ideal linear observerJournal of the Optical Society of America A, 2003
- Ideal-observer computation in medical imaging with use of Markov-chain Monte Carlo techniquesJournal of the Optical Society of America A, 2003
- Radiologists' Productivity in the Interpretation of CT ScansAmerican Journal of Roentgenology, 2001
- Objective assessment of image quality II Fisher information, Fourier crosstalk, and figures of merit for task performanceJournal of the Optical Society of America A, 1995
- Model observers for assessment of image quality.Proceedings of the National Academy of Sciences, 1993
- Objective assessment of image quality: effects of quantum noise and object variabilityJournal of the Optical Society of America A, 1990
- Lesion detection and signal–to–noise ratio in CT imagesMedical Physics, 1981