Use of the Inferior Whorl for Detecting Age-Related Changes in Human Corneal Subbasal Nerve Plexus with Laser Scanning Confocal Microscopy
Authors:
- Kuiqing ZhaoKZKuiqing Zhao
- Hua YuHYHua Yu
- Xiaofen ZhengXZXiaofen Zheng
- Jizhong YangJYJizhong Yang
- Xiaowu WangXWXiaowu Wang
- Yuping HanYHYuping Han
- Lijun JiaLJLijun Jia
- Juwei ZhaoJZJuwei Zhao
- 5 March 2020
- journal article
- research article
- Published by S. Karger AG in Ophthalmic Research
- Vol. 64 (5) , 769-774
Abstract
Purpose: The purpose of this study was to determine the effect of aging on the corneal subbasal nerve plexus (SNP) by employing a wide-field mapping technique of composite images, scanned at the location of a distinctive spiraled subbasal nerve pattern located 1–2 mm inferior to the corneal apex (the inferior whorl) for SNP structural quantification. Materials and Methods: Central corneal tactile sensitivity (CCTS) and inferior whorl length (IWL) were compared among individuals in 3 age-groups (20–39 years, 40–59 years, and 60–79 years). Statistical analyses constituted the Kruskal-Wallis test, one-way analysis of variance (with the post hoc least significant difference test), Spearman correlation coefficient, and linear regression analysis. Results: CCTS remained stable until the age of 50 years, when it began to decrease; the mean CCTS was 58.15 ± 2.46 mm in the group aged 20–39 years, 55.74 ± 3.85 mm in the group aged 40–59 years, and 50.23 ± 3.27 mm in the group aged 60–79 years. IWL decreased with increasing age, with a corresponding linear decline of 0.2088 mm/mm2 per year, and the mean IWL was 25.43 ± 4.50 mm/mm2 in the group aged 20–39 years, 22.71 ± 6.19 mm/mm2 in the group aged 40–59 years, and 18.60 ± 4.21 mm/mm2 in the group aged 60–79 years. Conclusion: Our work provided a more accurate and repeatable method for corneal nerve analysis using laser scanning confocal microscopy. By using this technique, we confirmed that aging is associated with progressive reduction in subbasal nerve length.Keywords
This publication has 24 references indexed in Scilit:
- Fully Automated Montaging of Laser Scanning In Vivo Confocal Microscopy Images of the Human Corneal Subbasal Nerve PlexusInvestigative Ophthalmology & Visual Science, 2012
- Reproducibility of in vivo corneal confocal microscopy as a novel screening test for early diabetic sensorimotor polyneuropathyDiabetic Medicine, 2011
- In Vivo Confocal Microscopy of Corneal Nerves: Analysis and Clinical CorrelationSeminars in Ophthalmology, 2010
- Mapping the entire human corneal nerve architectureExperimental Eye Research, 2010
- Real-time mapping of the subepithelial nerve plexus by in vivo confocal laser scanning microscopyBritish Journal of Ophthalmology, 2010
- In vivo confocal microscopy of human corneal nerves in health, in ocular and systemic disease, and following corneal surgery: a reviewBritish Journal of Ophthalmology, 2008
- Mapping of Normal Corneal K-Structures by In Vivo Laser Confocal MicroscopyCornea, 2008
- Corneal Involvement in Rheumatoid Arthritis: An In Vivo Confocal StudyInvestigative Ophthalmology & Visual Science, 2008
- Age-related differences in the normal human cornea: a laser scanning in vivo confocal microscopy studyBritish Journal of Ophthalmology, 2007
- Age-Related Modifications of Corneal SensitivityOphthalmologica, 2004