Continuous Direct Current Nerve Block Using Multi Contact High Capacitance Electrodes
- 9 July 2016
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 25 (6) , 517-529
Abstract
Charge-balanced direct current (CBDC) nerve block can be used to block nerve conduction in peripheral nerves. Previous work demonstrated that the CBDC waveform could be used to achieve a 10% duty cycle of block to non-block repeatedly for at least two hours. We demonstrate that the duty cycle of this approach can be significantly increased by utilizing multiple electrode contacts and cycling the CBDC waveform between each contact in a “carousel” configuration. Using this approach, we demonstrated in an acute rat sciatic nerve preparation, that a 30% duty cycle complete block can be achieved with two contacts; and a 100% duty cycle block (>95% complete block) can be achieved with four contacts. This latter configuration utilized a 4-s block plateau, with 3 s between successive plateaus at each contact and a recharge phase amplitude that was 34% of the block amplitude. Further optimization of the carousel approach can be achieved to improve block effectiveness and minimize total electrode length. This approach may have significant clinical use in cases where a partial or complete block of peripheral nerve activity is required. In one example case, we achieved continuous block for 22 min without degradation of nerve conduction. Future study will be required to further optimize this technique and to demonstrate safety for chronic human use.Keywords
Funding Information
- Case Coulter Translational Partnership Program National Institutes of Health, National Institute of Neurological Disorders and Stroke (1R01NS074149)
This publication has 49 references indexed in Scilit:
- Investigating the electrochemical windows of ionic liquidsJournal of Industrial and Engineering Chemistry, 2013
- Parylene-based implantable platinum-black coated wire microelectrode for orbicularis oculi muscle electrical stimulationBiomedical Microdevices, 2011
- Design, fabrication and evaluation of a conforming circumpolar peripheral nerve cuff electrode for acute experimental useJournal of Neuroscience Methods, 2011
- Frequency- and amplitude-transitioned waveforms mitigate the onset response in high-frequency nerve blockJournal of Neural Engineering, 2010
- Conduction block of whole nerve without onset firing using combined high frequency and direct currentMedical & Biological Engineering & Computing, 2010
- In vitro comparison of sputtered iridium oxide and platinum-coated neural implantable microelectrode arraysBiomedical Materials, 2010
- Chronic stability and selectivity of four-contact spiral nerve-cuff electrodes in stimulating the human femoral nerveJournal of Neural Engineering, 2009
- Effects of ramped amplitude waveforms on the onset response of high-frequency mammalian nerve blockJournal of Neural Engineering, 2007
- FINAL ANALYSISPlatinum Metals Review, 2007
- High‐frequency electrical conduction block of mammalian peripheral motor nerveMuscle & Nerve, 2005