Currently, studies connected with Computational Fluid Dynamic (CFD) techniques focus on assessing hemodynamic of blood flow in vessels in different conditions e.g. after stent-graft’s placement. The paper propose a novel method of standardization of results obtained from calculations of stent-grafts' “pushing forces” (cumulative WSS—Wall Shear Stress), and describes its usefulness in diagnostic process. AngioCT data from 27 patients were used to reconstruct 3D geometries of stent-grafts which next were used to create respective reference cylinders. We made an assumption that both the side surface and the height of a stent-graft and a reference cylinder were equal. The proposed algorithm in conjunction with a stent-graft “pushing forces” on an implant wall, allowed us to determine which spatial configuration of a stent-graft predispose to the higher risk of its migration. For stent-grafts close to cylindrical shape (shape factor φ close to 1) WSS value was about 267Pa, while for stent-grafts different from cylindrical shape (φ close to 2) WSS value was about 635Pa. It was also noticed that deformation in the stent-graft’s bifurcation part impaired blood flow hemodynamic. Concluding the proposed algorithm of standardization proved its usefulness in estimating the WSS values that may be useful in diagnostic process. Angular bends or tortuosity in bifurcations of an aortic implant should be considered in further studies of estimation of the risk of implantation failure.Keywords
Funding Information
- Narodowe Centrum Badań i Rozwoju (501/10-34-19-605)
- Narodowe Centrum Nauki (2011/01/B/ST8/06689)
This publication has 36 references indexed in Scilit:
- The Multi-Scale Modelling of Coronary Blood FlowAnnals of Biomedical Engineering, 2012
- Effects of stent-graft geometry and blood hematocrit on hemodynamic in Abdominal Aortic AneurysmChemical and Process Engineering: New Frontiers, 2012
- Optimization of Cardiovascular Stent Design Using Computational Fluid DynamicsJournal of Biomechanical Engineering, 2012
- Endograft Accommodation on the Aortic Bifurcation:An Overview of Anatomical Fixation and Implications for Long-term Stent-Graft StabilityJournal of Endovascular Therapy, 2011
- Numerical Investigation of the Performance of Three Hinge Designs of Bileaflet Mechanical Heart ValvesAnnals of Biomedical Engineering, 2010
- Patient-Based Abdominal Aortic Aneurysm Rupture Risk Prediction with Fluid Structure Interaction ModelingAnnals of Biomedical Engineering, 2010
- Late aneurysm rupture after endovascular abdominal aneurysm repairInteractive CardioVascular and Thoracic Surgery, 2007
- Non-Newtonian blood flow in human right coronary arteries: Transient simulationsJournal of Biomechanics, 2006
- A mathematical model to predict the in vivo pulsatile drag forces acting on bifurcated stent grafts used in endovascular treatment of abdominal aortic aneurysms (AAA)Journal of Biomechanics, 2004
- Predicting iliac limb occlusions after bifurcated aortic stent grafting: Anatomic and device-related causesJournal of Vascular Surgery, 2002