Real-Time Ultrasound Elastography in Multiple Sclerosis Spasticity: Comparison with Clinical and Neurophysiological Measures
Authors:
- Eleni BakolaEBEleni Bakola
- Marianna PapadopoulouMarianna Papadopoulou
- Maria-Ioanna StefanouMSMaria-Ioanna Stefanou
- Athanasios K. ChasiotisACAthanasios K. Chasiotis
- Stella FanourakiSFStella Fanouraki
- Angeliki-Erato SterpiASAngeliki-Erato Sterpi
- Dimitrios KitsosDKDimitrios Kitsos
- Georgios TsivgoulisGeorgios Tsivgoulis
Open Access
- 26 May 2026
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (11) , 4095
Abstract
Background: Spasticity is a common and disabling symptom of multiple sclerosis (MS), yet its assessment remains challenging. Clinical scales such as the Ashworth Scale (AS) evaluate resistance to passive movement, whereas neurophysiological measures (e.g., H-reflex, F-wave) provide objective indices of α-motoneuron excitability but correlate inconsistently with clinical severity. Real-time ultrasound elastography (RTE) enables semi-quantitative, in vivo assessment of muscle stiffness, while the recently introduced Muscle Elastography Multiple Sclerosis Score (MEMSs) aims to classify muscle spasticity in MS. Objective: To evaluate the utility of RTE using MEMSs for the objective assessment of muscle status in MS patients with spasticity, and to compare elastographic findings with clinical and neurophysiological measures. Methods: In this single-center study, 26 MS patients (diagnosed according to the 2017 McDonald criteria) and age- and sex-matched healthy controls (n = 27) were enrolled. Spasticity was graded using the AS. All participants underwent bilateral RTE of the gastrocnemius muscle, with images independently scored by two blinded neurologists using the 5-point MEMSs scale. Neurophysiological assessment included the soleus H-reflex, with calculation of H/M ratios. Correlations were analyzed using Pearson’s coefficient, and inter-observer reliability was assessed. Results: No consistent or statistically robust associations were found between clinical spasticity severity (AS scores) and either neurophysiological or elastographic parameters. Several MEMSs did not correlate reliably with AS grades, and neurophysiological measures showed limited discriminatory ability between MS patients and healthy controls. Correlations between neurophysiological and elastography parameters were weak to moderate (ρ ranging from −0.49 to 0.45). Inter-observer reliability of MEMSs scoring ranged from poor to moderate across the examined muscle groups, with Cohen’s κ values ranging from −0.02 to 0.54. Conclusions: RTE using MEMSs did not demonstrate sufficient validity or reproducibility for assessing muscle spasticity in MS, showing poor agreement with both clinical and neurophysiological measures.Keywords
This publication has 18 references indexed in Scilit:
- Assessment and Measurement of Spasticity in MS: State of the EvidenceCurrent Neurology and Neuroscience Reports, 2019
- Diagnosis of multiple sclerosis: 2017 revisions of the McDonald criteriaThe Lancet Neurology, 2018
- Muscle elastography: a new imaging technique for multiple sclerosis spasticity measurementNeurological Sciences, 2016
- Ultrasound elastography: Principles and techniquesDiagnostic and Interventional Imaging, 2013
- Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were proposedJournal of Clinical Epidemiology, 2011
- Is Sonoelastography of Value in Assessing Tendons?Seminars in Musculoskeletal Radiology, 2010
- Real-time ultrasound elastography of the normal Achilles tendon: reproducibility and pattern descriptionClinical Radiology, 2009
- Spasticity: Clinical perceptions, neurological realities and meaningful measurementDisability and Rehabilitation, 2005
- Neurophysiological methods for the assessment of spasticity: The Hoffmann reflex, the tendon reflex, and the stretch reflexDisability and Rehabilitation, 2005
- Interrater Reliability of a Modified Ashworth Scale of Muscle SpasticityPhysical Therapy, 1987