Fixation strength of taper connection at head–neck junction in retrieved carbon fiber-reinforced PEEK hip stems
- 5 September 2014
- journal article
- research article
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 17 (4) , 358-363
Abstract
Carbon fiber-reinforced polyetheretherketone (CFR-PEEK) hip prostheses possess numerous advantages over metal prostheses; however, the security of the taper connection between the CFR-PEEK stem and the modular femoral head in vivo has not been verified. Therefore, we mechanically examined the taper connection of retrieved in vivo loaded CFR-PEEK stems in comparison with in vivo loaded titanium alloy stems. CFR-PEEK and titanium alloy femoral stems with a 12/14 taper trunnion were implanted in ovine hips. A 22-mm ceramic head was intraoperatively impacted to the stem. Retrieved specimens were obtained following weight-bearing conditions for up to 39 postoperative weeks and taper junction pull-off tests were conducted. Postoperative retrieved CFR-PEEK stem pull-off strength was significantly greater than that at time zero. Postoperative retrieved CFR-PEEK stem pull-off strength was also significantly higher than that of postoperative retrieved titanium alloy stem. Microscopic findings of the taper surface revealed no obvious damage in the retrieved CFR-PEEK stems, whereas fretting and corrosion were observed in the retrieved titanium alloy stems. The present findings suggest that the taper connection between the ceramic head and the 12/14 CFR-PEEK stem trunnion is more secure than that between the ceramic head and the titanium alloy trunnion.Keywords
This publication has 34 references indexed in Scilit:
- Pseudotumour Formation Due to Tribocorrosion at the Taper Interface of Large Diameter Metal on Polymer Modular Total Hip ReplacementsThe Journal of Arthroplasty, 2013
- Accelerating failure rate of the ASR total hip replacementThe Journal of Bone and Joint Surgery. British volume, 2011
- The association between metal allergy, total hip arthroplasty, and revisionActa Orthopaedica, 2009
- Second-generation Extensively Porous-coated THA Stems at Minimum 10-year FollowupClinical Orthopaedics and Related Research, 2009
- Pseudotumours associated with metal-on-metal hip resurfacingsThe Journal of Bone and Joint Surgery. British volume, 2008
- Die Bedeutung der Setzkraft für die Sicherheit einer Konuskopplung von Hüftstiel und keramischem Prothesenkopf / Relevance of the insertion force for the taper lock reliability of a hip stem and a ceramic femoral headBiomedical Engineering / Biomedizinische Technik, 2006
- Long-term results of the metal-cancellous cementless Lübeck total hip arthroplasty: a critical review at 12.8 yearsArchives of orthopaedic and trauma surgery, 2005
- Long-term compressive property durability of carbon fibre-reinforced polyetheretherketone composite in physiological salineBiomaterials, 1996
- In vitro biocompatibility testing of polymers for orthopaedic implants using cultured fibroblasts and osteoblastsBiomaterials, 1995
- In vitro biocompatibility of polyetheretherketone and polysulfone compositesJournal of Biomedical Materials Research, 1990