Thermal capsulotomy: Initial clinical experience, intraoperative performance, safety, and early postoperative outcomes of precision pulse capsulotomy technology
- 1 March 2018
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 44 (3) , 355-361
Abstract
To assess the clinical safety and performance of a new thermal capsulotomy device in patients having cataract surgery. Launceston Eye Institute, Launceston, Tasmania, Australia. Prospective case series. This single-surgeon consecutive series comprised eyes having capsulotomy with a precision pulse capsulotomy (PPC) device (Zepto). Baseline demographic information and preoperative, intraoperative, and early postoperative outcomes, including complications, intraocular pressure (IOP), flare photometry, corneal and retinal thickness, and specular microscopy were collected and analyzed. Outcomes included PPC performance, intraoperative complications, effective phacoemulsification time, IOP, postoperative inflammation, corneal edema, endothelial cell density, functional evaluation of the corneal endothelium, retinal thickness, cost-effectiveness, and early postoperative visual acuity. The study evaluated 100 eyes. Complete free-floating capsulotomy was achieved in 70 eyes (72%). Focal attachments were identified in 17 eyes (18%) and broad attachments in 10 eyes (10%). Intended PPC capsulotomy failed in 3 eyes due to operator or device error. Anterior capsule tears occurred in 4 eyes (4%); otherwise, there were no significant safety signals in the early postoperative period. There was no evidence of a learning curve effect; however, use of a dispersive ophthalmic viscosurgical device (OVD) is postulated as influencing capsulotomy completeness. The PPC device created round, reproducible, appropriately sized capsulotomies in 72% of eyes. The incidence of incomplete capsulotomy and radial tear rate was high and was possibly associated with the use of a dispersive OVD.Keywords
This publication has 14 references indexed in Scilit:
- Comparison of Manual, Femtosecond Laser, and Precision Pulse Capsulotomy Edge Tear Strength in Paired Human Cadaver EyesOphthalmology, 2016
- Precision Pulse CapsulotomyOphthalmology, 2016
- Femtosecond laser–assisted capsulorhexis: Anterior capsule tags and tearsJournal of Cataract & Refractive Surgery, 2015
- Effect of femtosecond laser–assisted cataract surgery on the corneal endotheliumJournal of Cataract & Refractive Surgery, 2014
- Anterior chamber flare after femtosecond laser–assisted cataract surgeryJournal of Cataract & Refractive Surgery, 2013
- Functional evaluation of corneal endothelium by combined measurement of corneal volume alteration and cell density after phacoemulsificationJournal of Cataract & Refractive Surgery, 2007
- Subjective difficulty of each stage of phacoemulsification cataract surgery performed by basic surgical traineesJournal of Cataract & Refractive Surgery, 2006
- An improved universal theoretical formula for intraocular lens power predictionJournal of Cataract & Refractive Surgery, 1993
- Strength of the lens capsule during hydroexpression of the nucleusJournal of Cataract & Refractive Surgery, 1993
- Development, advantages, and methods of the continuous circular capsulorhexis techniqueJournal of Cataract & Refractive Surgery, 1990