Rapid on‐site assessment of specimens by biomedical scientists improves the quality of head and neck fine needle aspiration cytology
Open Access
- 21 October 2013
- journal article
- research article
- Published by Wiley in Cytopathology
- Vol. 25 (5) , 316-321
Abstract
Objective: Immediate rapid on‐site assessment (ROSA) of fine needle aspiration cytology (FNAC) specimens by biomedical scientists (BMS), the UK equivalent of cytotechnologists, or by pathologists may improve specimen quality and cellular adequacy rates for lymph node, head and neck and thyroid FNAC. The aim of this study was to evaluate the effect of introducing ROSA by BMS in an outpatient clinic setting.Methods: The adequacy rate and sensitivity of histological diagnosis for lymph node, thyroid and salivary gland FNAC samples were determined before and after the introduction of BMS ROSA. The additional financial costs and time required to perform this service were also estimated.Results: Thirty‐one patients underwent ultrasound (US)‐guided FNAC with ROSA and 151 without. ROSA reduced the number of FNAC insufficient in quality for diagnosis from 43% to 19% (P = 0.0194). The estimated additional cost for pathology per patient for ROSA was between £52.05 and £70.74, equivalent to €65.40/US $83.90 and €88.89/US $114.0, respectively, an increase of between 28% and 49% from the original cost. ROSA necessitated an additional 6 minutes clinic time per patient, reducing the number of patients that could be seen in an average clinic from 13 to 10 as well as requiring increased laboratory time for FNAC slide assessment.Conclusion: ROSA by suitably trained biomedical scientists and with appropriate consultant pathologist support can improve the quality of FNAC sampling for head and neck lesions. Although ROSA resulted in both additional financial and time costs, these are more than likely to be offset by a reduction in patients returning to clinic for repeat FNAC or undergoing unnecessary surgery.Keywords
This publication has 14 references indexed in Scilit:
- Ultrasound‐guided needle aspiration: Impact of immediate cytologic reviewThe Laryngoscope, 2010
- BSCC Code of Practice – fine needle aspiration cytologyCytopathology, 2009
- Head and neck cancer in the UK: what is expected of cytopathology?Cytopathology, 2009
- Assessment of the Cost of Fine-Needle Aspiration Cytology as a Diagnostic Tool in Patients With Thyroid NodulesAmerican Journal of Clinical Pathology, 2008
- Fine‐needle aspiration in the diagnosis of head and neck lesions: A review and discussion of problems in differential diagnosisDiagnostic Cytopathology, 2007
- Diagnostic adequacy and accuracy of fine needle aspiration cytology in neck lump assessment: results from a regional cancer network over a one year periodThe Journal of Laryngology & Otology, 2006
- The value of onsite adequacy assessment of thyroid fine-needle aspirations is a function of operator experienceCancer, 2006
- The Impact of Assessing Specimen Adequacy and Number of Needle Passes for Fine-Needle Aspiration Biopsy of Thyroid NodulesThyroid®, 2006
- Cost-Effectiveness of Immediate Specimen Adequacy Assessment of Thyroid Fine-Needle AspirationsAmerican Journal of Clinical Pathology, 2004
- Diagnostic value and cost‐effectiveness of on‐site evaluation of fine‐needle aspiration specimens: Review of 5,688 casesDiagnostic Cytopathology, 2002