Due to its high power densities and compact dimensions, the axial flux coreless permanent magnet synchronous generator (PMSG) is used in a wide range of areas such as wind turbines and electric vehicles. It is extremely important to detect magnetization faults that occur in these generators. The occurrence of such faults in these machines with a wide range of areas of use affects their operation negatively. In this study, an effective method has been proposed to detect the demagnetization fault occurring in axial flux coreless PMSGs. The relevant method proposes an effective texture analysis-based feature extraction method, which is an original method in contrast to conventional methods used in the literature. It has been revealed that it is a method that can be used instead of conventional methods such as time-frequency analysis, frequency spectrum analysis, and motor current signature analysis (MCSA) methods. Using the finite element method, current and voltage signals were taken from the healthy and axial flux coreless PMSG with 3% and 6% demagnetization fault. Besides, these signals were retaken at different speeds and loads. After the signals were converted into images, using the features obtained from the images with LBP, fault diagnosis processes were carried out with Knn. It was tested both at different fault rates and under different load and speed conditions to test whether the proposed method worked properly. The success rate of this method was observed as 97.16% and 100%. With the proposed method, it has been revealed that the demagnetization fault can be detected in axial flux coreless PMSGs.Keywords
Funding Information
- Special Electrical Laboratory, Siirt University
This publication has 45 references indexed in Scilit:
- Identification of Demagnetization Faults in Axial Flux Permanent Magnet Synchronous Machines Using an Inverse Problem Coupled With an Analytical ModelIEEE Transactions on Magnetics, 2014
- Fault Diagnosis of a Wind Turbine Benchmark via Identified Fuzzy ModelsIEEE Transactions on Industrial Electronics, 2014
- A Comprehensive Review of Axial-Flux Permanent-Magnet MachinesCanadian Journal of Electrical and Computer Engineering, 2014
- Multipolar SPM Machines for Direct-Drive Application: A General Design ApproachIEEE Transactions on Industry Applications, 2013
- Fault diagnosis of induction motors utilizing local binary pattern-based texture analysisEURASIP Journal on Image and Video Processing, 2013
- A simple method for improving local binary patterns by considering non-uniform patternsPattern Recognition, 2012
- Pattern identification for eccentricity fault diagnosis in permanent magnet synchronous motors using stator current monitoringIET Electric Power Applications, 2010
- Fault detection and fault-tolerant control of interior permanent-magnet motor drive system for electric vehicleIEEE Transactions on Industry Applications, 2005
- Multiresolution gray-scale and rotation invariant texture classification with local binary patternsIEEE Transactions on Pattern Analysis and Machine Intelligence, 2002
- Performance comparisons of radial and axial field, permanent-magnet, brushless machinesIEEE Transactions on Industry Applications, 2001