Abstract
Exploiting photoplethysmography signals (PPG) for non-invasive blood pressure (BP) measurement is interesting for various reasons. First, PPG can easily be measured using fingerclip sensors. Second, camera-based approaches allow to derive remote PPG (rPPG) signals similar to PPG and therefore provide the opportunity for non-invasive measurements of BP. Various methods relying on machine learning techniques have recently been published. Performances are often reported as the mean average error (MAE) on the data which is problematic. This work aims to analyze the PPG- and rPPG-based BP prediction error with respect to the underlying data distribution. First, we train established neural network (NN) architectures and derive an appropriate parameterization of input segments drawn from continuous PPG signals. Second, we apply this parameterization to a larger PPG dataset and train NNs to predict BP. The resulting prediction errors increase towards less frequent BP values. Third, we use transfer learning to train the NNs for rPPG based BP prediction. The resulting performances are similar to the PPG-only case. Finally, we apply a personalization technique and retrain our NNs with subject-specific data. This slightly reduces the prediction errors.Keywords
All Related Versions
This publication has 48 references indexed in Scilit:
- A new look at the essence of the imaging photoplethysmographyScientific Reports, 2015
- Cuff-less high-accuracy calibration-free blood pressure estimation using pulse transit time2015
- Detection of c, d, and e waves in the acceleration photoplethysmogramComputer Methods and Programs in Biomedicine, 2014
- Improved motion robustness of remote-PPG by using the blood volume pulse signaturePhysiological Measurement, 2014
- Systolic Peak Detection in Acceleration Photoplethysmograms Measured from Emergency Responders in Tropical ConditionsPLOS ONE, 2013
- Pulse arrival time is not an adequate surrogate for pulse transit time as a marker of blood pressureJournal of Applied Physiology, 2011
- Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based methodEuropean Journal of Applied Physiology, 2011
- Normal Vascular Aging: Differential Effects on Wave Reflection and Aortic Pulse Wave VelocityJACC, 2005
- Evaluation of the pulse wave arrival time as a marker for blood pressure changes in critically ill infants and childrenJournal of Clinical Monitoring and Computing, 1995