Multilayer Cylindrical Magnetic Shield for SERF Atomic Co-Magnetometer Application
- 28 December 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (8) , 2916-2923
Abstract
This study presents the development of a SERF atomic co-magnetometer with a magnetic shielding system. The shielding system includes multiple cylindrical passive magnetic shield and active magnetic compensation coils. The multilayer shield, which adopts a structural style comprising a barrel body and end cover, is applied to attenuate the external magnetic field to less than 10 nT or ideally close to zero. For the purpose of degaussing, pumping, and probing light paths, several openings must be made on the magnetic shield. A hybrid approach combining theoretical calculations and the finite element method is proposed to analyze the shielding properties, considering the influence of openings. To evaluate the shielding properties of the magnetic shield, two different simplified finite element models are established and analyzed. The simulation results are compared with theoretical and experimental data, and the results are in good agreement. The modeled results show that the openings bear a considerable influence on the shielding performance, and thus, their effect cannot be ignored. The axial magnetic shielding factor with several openings is roughly 4.4×104, which is about two orders of magnitude lower than that without openings. Further, a rotation sensitivity of 5.86×10–7rad·s–1·Hz–1/2 is obtained with the open-hole magnetic shield. This sensitivity corresponds to a magnetic sensitivity of 27.8 fT/Hz1/2. Based on the results, possible improvements are suggested for future designs.Keywords
Funding Information
- Natural Science Foundation of Beijing Municipality (19D10003)
- Key Programs of the National Science Foundation of China (2016YFB051600)
- National Natural Science Foundation of China (617733043, 61721091)
This publication has 32 references indexed in Scilit:
- New Limit on Lorentz- and-Violating Neutron Spin InteractionsPhysical Review Letters, 2010
- Limits on New Long Range Nuclear Spin-Dependent Forces Set with aComagnetometerPhysical Review Letters, 2009
- Spin-exchange-relaxation-free magnetometry with Cs vaporPhysical Review A, 2008
- Demonstration of high-performance compact magnetic shields for chip-scale atomic devicesReview of Scientific Instruments, 2007
- Optical magnetometryNature Physics, 2007
- Nuclear Spin Gyroscope Based on an Atomic ComagnetometerPhysical Review Letters, 2005
- Nonlinear Amplification of Small Spin Precession Using Long-Range Dipolar InteractionsPhysical Review Letters, 2005
- Principles of quasistatic magnetic shielding with cylindrical and spherical shieldsIEEE Transactions on Electromagnetic Compatibility, 1995
- Conventional magnetic shieldingJournal of Physics D: Applied Physics, 1987
- Shielding of Low Magnetic Fields with Multiple Cylindrical ShellsReview of Scientific Instruments, 1971