Mean Oxygen Saturation in Well Neonates at Altitudes Between 4498 and 8150 Feet
Authors:
- Patricia RavertPRPatricia Ravert
- Tracie Line DetwilerTDTracie Line Detwiler
- Jane K. DickinsonJDJane K. Dickinson
- 1 December 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Advances in Neonatal Care
- Vol. 11 (6) , 412-417
Abstract
Examine changes in oxygen saturation in well neonates at altitudes from 4498 to 8150 feet with serial measurements at 12 to 24 hours of age, 36 to 48 hours, and, if still hospitalized, at 60 to 72 hours. Convenience sample of well newborn infants meeting inclusion criteria of normal cardiopulmonary status (centrally pink with adequate perfusion) and no respiratory distress (absence of grunting, retracting, nasal flaring, or tachypnea-respiration ≤ 60/minute). Nonexperimental, longitudinal, descriptive study. Using Masimo Radical SET monitors the SpO2 values were recorded from infant's right upper extremity to obtain a preductal measurement and then from left lower extremity for postductal measurement at study intervals. SpO2 values. The well neonates' birth weights ranged from 1835 to 4740 g [corrected], with 94.3% classified as term and 5.7% classified as preterm. At the data collection intervals based on hours of life, mean SpO2 readings at 4498 feet were 95% to 96.67%, at 6800 feet were 93.91% to 95.36%, at 7851 feet were 91.80% to 94.37%, at 7890 feet were 93.44% to 96.10%, and at 8150 feet were 93.69% to 96.25%. SpO2 readings at sites at or above 6800 feet were significantly lower than those at 4498 feet. No significant differences were noted for sleep state or season. Significant differences were noted in the first and second lower extremity readings between preterm and term neonates, with preterm SpO2 readings higher than term readings. Mean oxygen saturation levels for well neonates born at higher altitudes are lower than those born at 4498 feet. Neonates born at or above 6800 feet exhibit "normal" oxygen saturation levels between 91% to 96% rather than the expected 97% found at sea level. These reference values for varying altitudes can guide clinicians to avoid hypoxemia or hyperoxia. If routine oxygen saturation screening for detection of critical congenital heart defects is implemented, these results will provide clinicians the mean values specific for additional altitudes, thus preventing unnecessary interventions when results are lower than the expected 97%.Keywords
This publication has 18 references indexed in Scilit:
- Noteworthy Professional NewsAdvances in Neonatal Care, 2010
- Implication of Pulse Oxymetry Screening for Detection of Congenital Heart DefectsKlinische Padiatrie, 2010
- Pulse oximetry screening as a complementary strategy to detect critical congenital heart defectsActa Paediatrica, 2009
- Critical heart defects—the diagnostic challengeActa Paediatrica, 2008
- The contribution of pulse oximetry to the early detection of congenital heart disease in newbornsEuropean Journal of Pediatrics, 2005
- Combining Pulse Oximetry and Clinical Examination in Screening for Congenital Heart DiseasePediatric Cardiology, 2005
- Cardiopulmonary Transition in the High Altitude InfantHigh Altitude Medicine & Biology, 2003
- Pulse oximeters’ reliability in detecting hypoxemia and bradycardia: Comparison between a conventional and two new generation oximetersCritical Care Medicine, 2000
- Pulse Oximetry: Implications for PracticeJournal of Obstetric, Gynecologic, & Neonatal Nursing, 1992
- Oxygen Saturation by Pulse Oximetry in Healthy Infants at an Altitude of 1610 m (5280 ft)American Journal of Diseases of Children, 1991