Statistically Rigorous and Interpretable Radiomics for Benign–Malignant Classification on the BUSI-WHU Breast Ultrasound Dataset
Open Access
- 15 September 2026
- journal article
- research article
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- p. 1-18
Abstract
Radiomics has shown promise for breast ultrasound lesion classification, yet reported performance is often affected by patient-level leakage, feature selection bias, dependence between lesions from the same patient, and image formats lacking pixel-spacing metadata. The BUSI-WHU dataset allows these issues to be addressed together. We analyzed 927 breast lesions from 816 patients using 939 handcrafted radiomic features from expert-annotated images. Pixel spacing was recovered from dataset-supplied scale factors and images resampled to a common isotropic resolution. Features were assessed by Mann–Whitney U tests with Benjamini–Hochberg correction and Cliff’s delta, with a one-lesion-per-patient sensitivity analysis. Six classifiers, including a penalized logistic regression baseline, were evaluated under ten-fold patient-grouped, class-stratified cross-validation with correlation filtering and Boruta selection inside each training fold. Confidence intervals and paired comparisons used patient-level bootstrap of out-of-fold predictions, and SHAP was computed on held-out patients. Of the 939 features, 587 differed significantly after correction; most remained significant under one-lesion-per-patient sampling; and 48 were selected consistently across folds. Pooled out-of-fold ROC-AUCs ranged from 0.828 to 0.834; no pairwise difference survived correction, and the logistic regression performed comparably to the best ensemble. Discrimination was unchanged when absolute size features were removed. Calibration did not follow discrimination: the two highest-ranked models were systematically overconfident, whereas the random forest was well calibrated despite equivalent discrimination. SHAP attributions were dominated by filtered texture. Radiomic features gave moderate discrimination under calibrated, leakage-resistant, patient-clustered evaluation. Classifier differences were minimal, no ensemble improved on a transparent linear model, and predicted probabilities would need recalibration before use.Keywords
This publication has 33 references indexed in Scilit:
- Computer‐aided diagnosis of breast ultrasound images using ensemble learning from convolutional neural networksComputer Methods and Programs in Biomedicine, 2020
- A systematic review reporting quality of radiomics research in neuro-oncology: toward clinical utility and quality improvement using high-dimensional imaging featuresBMC Cancer, 2020
- Quality of science and reporting of radiomics in oncologic studies: room for improvement according to radiomics quality score and TRIPOD statementEuropean Radiology, 2019
- BI-RADS 4 breast lesions: could multi-mode ultrasound be helpful for their diagnosis?Gland Surgery, 2019
- Computational Radiomics System to Decode the Radiographic PhenotypeCancer Research, 2017
- Radiomics: Images Are More than Pictures, They Are DataRadiology, 2016
- Radiomics: Extracting more information from medical images using advanced feature analysisEuropean Journal of Cancer, 2012
- BI-RADS for Sonography: Positive and Negative Predictive Values of Sonographic FeaturesAmerican Journal of Roentgenology, 2005
- Comparing the Areas under Two or More Correlated Receiver Operating Characteristic Curves: A Nonparametric ApproachBiometrics, 1988
- Note on the Sampling Error of the Difference Between Correlated Proportions or PercentagesPsychometrika, 1947