Fluidic Glucose Measurement Based on a Differential Microwave Sensing System With Combination of Multistepped-Impedance Transmission Lines
- 2 August 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (18) , 28805-28817
Abstract
A differential microwave sensing system based on short-ended multi-stepped-impedance transmission lines (MSITL) for measuring blood glucose concentration in binary solution is put forward in this manuscript. The phase of reflection coefficient of MSITL is adopted to detect glucose concentration. In order to obtain the high sensitivity, the change ratio of phase of reflection coefficient and glucose concentration should be maximum. The derivative mathematical model between phase of reflection coefficient and glucose concentration/permittivity should be established, the optimized geometrical parameter values are derived by solving the maximum value of derivative mathematical model. Then, a three stepped-impedance transmission line is implemented to demonstrate the correctness of analysis. The differential structure is obtained by symmetrically replicate the multi-stepped-impedance transmission lines. After finishing the design of multi-stepped-impedance transmission lines, a reflective RF oscillator is designed to transform the relationship between phase of reflection coefficient and glucose concentration/permittivity into the relation between oscillation frequency and glucose concentration/permittivity. Then, power divider, phase shifter, and phase detector are added to constitute the microwave sensing system. The microwave sensing system can translate the bearing between oscillation frequency and glucose concentration into the relation between output DC voltage and glucose concentration. Finally, the fitting curve formula is obtained to predict the unknown glucose concentration. In measurement, the microwave sensing system shows an average sensitivity of about 53.897 uV /( mg / dL ), and the maximum error is about 10.38%. Besides, the minimum detectable concentration is about 12.5 mg/dL, and the resolution is several times higher than other reported ones. The proposed microwave sensing system is a good choice in the application of characterizing liquid solutions.Keywords
Funding Information
- National Natural Science Foundation of China (62222401, 62171168)
- Zhejiang Provincial Natural Science Foundation (LXR22F040001, LY22F010020)
This publication has 64 references indexed in Scilit:
- Compact Tetracyclic Nested AMC-Backed Multiband Antenna With High OoB Rejection and Enhanced Gain Radiation for IIoV-Based Sensing and CommunicationIEEE Internet of Things Journal, 2023
- A dual-mode microwave sensor for edible oil characterization using magnetic-LC ResonatorsSensors and Actuators A: Physical, 2022
- Microwave reflective biosensor for glucose level detection in aqueous solutionsSensors and Actuators A: Physical, 2020
- Dual-Mode Resonator for Simultaneous Permittivity and Thickness Measurement of DielectricsIEEE Sensors Journal, 2019
- An Analytical Method to Implement High-Sensitivity Transmission Line Differential Sensors for Dielectric Constant MeasurementsIEEE Sensors Journal, 2019
- Microwave Sensor for Liquid Dielectric Characterization Based on Metamaterial Complementary Split Ring ResonatorIEEE Sensors Journal, 2018
- Differential Sensors Using Microstrip Lines Loaded With Two Split-Ring ResonatorsIEEE Sensors Journal, 2018
- Multi-Band RF Planar Sensor Using Complementary Split Ring Resonator for Testing of Dielectric MaterialsIEEE Sensors Journal, 2018
- Submersible Printed Split-Ring Resonator-Based Sensor for Thin-Film Detection and Permittivity CharacterizationIEEE Sensors Journal, 2016
- Dual-mode behavior of the complementary electric-LC resonators loaded on transmission line: Analysis and applicationsJournal of Applied Physics, 2014