Robust wide‐area impedance‐based fault location method utilising LAV estimator
Authors:
Open Access
- 1 July 2016
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 10 (10) , 2475-2485
Abstract
This study presents a robust method for detecting the location of fault in the wide‐area power networks considering the limited number of synchronised phasor measurement units. In this manner, by employing the positive‐sequence components in the governing equations at pre‐ and post‐fault occurrence, the fault location (FL) problem is formulated as an optimisation problem. The constructed objective function consists of two terms that are dependent on the voltage and current changes so that each of them can be employed in the optimisation procedure, alone. Various factors, such as cyber attacks and measurement device failures, may lead to induce the bad data to the measurement set, and thus the results will not be valid. Automatic detection and elimination of erroneous measurements, contaminated with gross errors, from the measurement set, will be carried out utilising the least absolute value (LAV) estimator. This is the most important property of the LAV estimator, in which the bad measurements will be screened and suppressed during the iterative optimisation. An algorithm based on LAV estimation is presented to identify the FL. The efficiency of the proposed method is not affected by fault type and resistance. The method is tested on IEEE 14‐bus, 57‐bus and 118‐bus case studies and simulation results indicate the accuracy of the developed technique.Keywords
This publication has 33 references indexed in Scilit:
- Fault location observability analysis and optimal meter placement based on voltage measurementsElectric Power Systems Research, 2009
- A Universal Fault Location Technique for N-Terminal $({N}\geqq 3)$ Transmission LinesIEEE Transactions on Power Delivery, 2008
- Transmission Network Fault Location Observability With Minimal PMU PlacementIEEE Transactions on Power Delivery, 2006
- Fault Location Scheme for a Multi-Terminal Transmission Line Using Synchronized Voltage MeasurementsIEEE Transactions on Power Delivery, 2005
- A New PMU-Based Fault Detection/Location Technique for Transmission Lines With Consideration of Arcing Fault Discrimination—Part I: Theory and AlgorithmsIEEE Transactions on Power Delivery, 2004
- Fault Location on a Transmission Line Using Synchronized Voltage MeasurementsIEEE Transactions on Power Delivery, 2004
- Distance protection and fault location utilizing only phase current phasorsIEEE Transactions on Power Delivery, 1998
- Unsynchronized two-terminal fault location estimationIEEE Transactions on Power Delivery, 1996
- Least absolute value state estimation with equality and inequality constraintsIEEE Transactions on Power Systems, 1993
- A technique for estimating transmission line fault locations from digital impedance relay measurementsIEEE Transactions on Power Delivery, 1988