Validation of an In Vivo Medical Image-Based Young Human Lumbar Spine Finite Element Model
- 18 January 2019
- journal article
- research article
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 141 (3)
Abstract
Mathematical models of the human spine can be used to investigate spinal biomechanics without the difficulties, limitations, and ethical concerns associated with physical experimentation. Validation of such models is necessary to ensure that the modeled system behavior accurately represents the physics of the actual system. The goal of this work was to validate a medical image-based nonlinear lumbosacral spine finite element model of a healthy 20-yr-old female subject under physiological moments. Range of motion (ROM), facet joint forces (FJF), and intradiscal pressure (IDP) were compared with experimental values and validated finite element models from the literature. The finite element model presented in this work was in good agreement with published experimental studies and finite element models under pure moments. For applied moments of 7.5 N·m, the ROM in flexion–extension, axial rotation, and lateral bending were 39 deg, 16 deg, and 28 deg, respectively. Excellent agreement was observed between the finite element model and experimental data for IDP under pure compressive loading. The predicted FJFs were lower than those of the experimental results and validated finite element models for extension and torsion, likely due to the nondegenerate properties chosen for the intervertebral disks and morphology of the young female spine. This work is the first to validate a computational lumbar spine model of a young female subject. This model will serve as a valuable tool for predicting orthopedic spinal injuries, studying the effect of intervertebral disk replacements using advanced biomaterials, and investigating soft tissue degeneration.Keywords
This publication has 55 references indexed in Scilit:
- Human annulus fibrosus material properties from biaxial testing and constitutive modeling are altered with degenerationBiomechanics and Modeling in Mechanobiology, 2011
- Finite Element Lumbar Spine Facet Contact Parameter Predictions are Affected by the Cartilage Thickness Distribution and Initial Joint Gap SizeJournal of Biomechanical Engineering, 2011
- Effect of the cord pretension of the Dynesys dynamic stabilisation system on the biomechanics of the lumbar spine: a finite element analysisEuropean Spine Journal, 2011
- Effect of multilevel lumbar disc arthroplasty on spine kinematics and facet joint loads in flexion and extension: a finite element analysisEuropean Spine Journal, 2010
- Geometry of the Intervertebral Volume and Vertebral Endplates of the Human SpineAnnals of Biomedical Engineering, 2009
- Application of a new calibration method for a three-dimensional finite element model of a human lumbar annulus fibrosusClinical Biomechanics, 2006
- Single lamellar mechanics of the human lumbar anulus fibrosusBiomechanics and Modeling in Mechanobiology, 2004
- Multi-segment FEA of the human lumbar spine including the heterogeneity of the annulus fibrosusComputational Mechanics, 2004
- Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implantsEuropean Spine Journal, 1998
- Mechanical Response of a Lumbar Motion Segment in Axial Torque Alone and Combined with CompressionSpine, 1986