A surrogate model for plaque modeling in carotids based on Robin conditions calibrated by cine MRI data
- 14 February 2021
- journal article
- research article
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 37 (5)
Abstract
We propose a surrogate model for the Fluid–Structure Interaction (FSI) problem for the study of blood dynamics in carotid arteries in presence of plaque. This is based on the integration of a numerical model with subject‐specific data and clinical imaging. We propose to model the plaque as part of the tissues surrounding the vessel wall through the application of an elastic support boundary condition. In order to characterize the plaque and other surrounding tissues, such as the close‐by jugular vein, the elastic parameters of the boundary condition were spatially differentiated and their values were estimated by minimizing the discrepancies between computed vessel displacements and reference values obtained from CINE Magnetic Resonance Imaging data. We applied the model to three subjects with a degree of stenosis greater than 70%. We found that accounting for both plaque and jugular vein in the estimation of the elastic parameters increases the accuracy. In particular, in all patients, mismatches between computed and in vivo measured wall displacements were 1–2 orders of magnitude lower than the spatial resolution of the original MRI data. These results confirmed the validity of the proposed surrogate plaque model. We also compared fluid‐dynamics results with those obtained in a fixed wall setting and in a full FSI model, used as gold standard, highlighting the better accordance of our results in comparison to the rigid ones.Keywords
This publication has 60 references indexed in Scilit:
- A mathematical evaluation of hemodynamic parameters after carotid eversion and conventional patch angioplastyAmerican Journal of Physiology-Heart and Circulatory Physiology, 2013
- Correlations between carotid plaque progression and mechanical stresses change sign over time: a patient follow up study using MRI and 3D FSI modelsBioMedical Engineering OnLine, 2013
- External tissue support and fluid–structure simulation in blood flowsBiomechanics and Modeling in Mechanobiology, 2011
- Introduction to the biomechanics of carotid plaque pathogenesis and rupture: review of the clinical evidenceBritish Journal of Radiology, 2010
- Outflow Conditions for Image-Based Hemodynamic Models of the Carotid Bifurcation: Implications for Indicators of Abnormal FlowJournal of Biomechanical Engineering, 2010
- An efficient two-stage approach for image-based FSI analysis of atherosclerotic arteriesBiomechanics and Modeling in Mechanobiology, 2009
- Direct numerical simulation of transitional flow in a stenosed carotid bifurcationJournal of Biomechanics, 2008
- A projection semi‐implicit scheme for the coupling of an elastic structure with an incompressible fluidInternational Journal for Numerical Methods in Engineering, 2006
- Variation in the Carotid Bifurcation Geometry of Young Versus Older AdultsStroke, 2005
- Computer Simulation and Geometric Design of Endarterectomized Carotid Artery BifurcationsCritical Reviews in Biomedical Engineering, 2000