UNCERTAINTY ANALYSIS OF THE RATIONAL FUNCTION MODEL USED IN THE COMPLEX PERMITTIVITY MEASUREMENT OF BIOLOGICAL TISSUES USING PMCT PROBES WITHIN A WIDE MICROWAVE FREQUENCY BAND
Authors:
- Zhanxian WangZWZhanxian Wang
- Wenquan CheWCWenquan Che
- Lixue ZhouLZLixue Zhou
- 1 January 2009
- journal article
- Published by The Electromagnetics Academy in Progress In Electromagnetics Research
- Vol. 90, 137-150
Abstract
The PMCT probe, saying, one kind of open-ended coaxial probe adopted widely in microwave coagulation therapy of cancer, has been used to measure the complex permittivity of freshly excised specimens of normal animal tissues. The RFM model for PMCT probe is developed to extract the anticipant permittivity of specimens under test. In addition, the efiects of several factors on the measurement results have been considered and discussed, including difierent temperature and reference materials, as well as the sampling frequency range and intervals of the rational function model. All the experiments have been conducted at the microwave frequency range from 450MHz to 14.5GHz.Keywords
This publication has 13 references indexed in Scilit:
- MEASUREMENT OF COMPLEX PERMITTIVITY OF LIQUIDS USING WAVEGUIDE TECHNIQUES - ABSTRACTJournal of Electromagnetic Waves and Applications, 2003
- Effects of mechanical flaws in open-ended coaxial probes for dielectric spectroscopyIEEE Microwave and Wireless Components Letters, 2002
- Permittivity Profile Reconstructions Using Transient Electromagnetic Reflection DataJournal of Electromagnetic Waves and Applications, 1998
- Admittance models for open ended coaxial probes and their place in dielectric spectroscopyPhysics in Medicine & Biology, 1994
- Dielectric measurements using a rational function modelIEEE Transactions on Microwave Theory and Techniques, 1994
- A new aperture admittance model for open-ended waveguidesIEEE Transactions on Microwave Theory and Techniques, 1994
- Temperature sensitivity of coaxial probe complex permittivity measurements: experimental approachIEEE Transactions on Microwave Theory and Techniques, 1993
- Permittivity measurements using open-ended sensors and reference liquid calibration-an uncertainty analysisIEEE Transactions on Microwave Theory and Techniques, 1992
- Measurement of Radio Frequency Permittivity of Biological Tissues with an Open-Ended Coaxial Line: Part IIEEE Transactions on Microwave Theory and Techniques, 1982
- Coaxial Line Reflection Methods for Measuring Dielectric Properties of Biological Substances at Radio and Microwave Frequencies-A ReviewIEEE Transactions on Instrumentation and Measurement, 1980