Characterization of monoclonal antibodies using polymeric cation exchange monoliths in combination with salt and pH gradients
- 7 August 2009
- journal article
- research article
- Published by Wiley in Journal of Separation Science
- Vol. 32 (15-16) , 2668-2673
Abstract
The characterization of three different mAb formulations of pharmaceutical interest is demonstrated using cation exchange polymethacrylate‐based monolithic columns as well as imaged CE (iCE). Elution of the mAbs from both a strong cation exchanger (ProSwiftTM SCX‐1S) and a weak cation exchanger (ProSwift WCX‐1S) was readily achieved employing a linear salt gradient or a mixed buffer pH gradient indicating that either approach can be used in purification or isolation. Using a linear salt gradient, the elution profile on the two types of exchangers was found to differ indicating that the combination of both strong and weak ion exchangers is needed for complete characterization. The elution profile of two of the mAbs on the strong cation exchanger used in combination with a linear pH gradient from pH 4 to 10 showed signs of charge heterogeneity. The use of iCE was found to be the best choice for characterization of charge heterogeneity, showing a clear charge distribution for all three mAbs.Keywords
Funding Information
- Australian Research Council for an ARC Federation Fellowship (FF0668673)
This publication has 20 references indexed in Scilit:
- Human IgG2 Antibodies Display Disulfide-mediated Structural IsoformsJournal of Biological Chemistry, 2008
- Comparison of standard and new generation hydrophobic interaction chromatography resins in the monoclonal antibody purification processJournal of Chromatography A, 2008
- Protein therapeutics: a summary and pharmacological classificationNature Reviews Drug Discovery, 2008
- Optimization of monoclonal antibody purification by ion-exchange chromatographyJournal of Chromatography A, 2005
- High‐performance liquid chromatographic profiling of fluorescent labelled N‐glycans on glycoproteinsBiomedical Chromatography, 2002
- Identification of κ and λ chains of the major immunoglobulin G subclasses by capillary zone electrophoresisBiomedical Chromatography, 2002
- Effect of buffer concentration on gradient chromatofocusing performance separating proteins on a high-performance DEAE columnJournal of Chromatography A, 2001
- High-performance chromatofocusing using linear and concave pH gradients formed with simple buffer mixturesJournal of Chromatography A, 2000
- Capillary isoelectric focusing as a tool in the examination of antibodies, peptides and proteins of pharmaceutical interestJournal of Chromatography A, 1996
- Chromatofocusing: Isoelectric focusing on ion-exchange columnsJournal of Chromatography A, 1978