‘Ease of adaptation’ predicts preferred spectacle prescriptions better than visual acuity: a retrospective analysis
Open Access
- 2 January 2024
- journal article
- research article
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 108 (1) , 79-86
Abstract
Clinical relevance: Factors predicting patient acceptance of a new spectacle prescription need to be determined to make optimal prescribing decisions.Background: Clinicians usually prescribe for best visual acuity. However, for some patients, a partial change is prescribed to ease adaptation, despite providing suboptimal visual acuity. This study seeks to develop an understanding of which factors predict patient preference between spectacle prescriptions by using a retrospective analysis to compare ease of adaptation, subjective quality of distance vision and optimal distance visual acuity.Methods: A retrospective analysis utilised a 196-patient data set in which participants wore two prescriptions, one based on the subjective refraction of an optometrist modified by judgement and one on autorefractor results modified for ease of adaptation by an algorithm. Spectacles were worn for 3 weeks each, and participants responded to questions about which prescription they preferred and their quality of distance vision and ease of adaptation (on a 0-10 scale) with each prescription. A logistic regression analysed which variables predicted whether participants responded yes or no to the question 'If you had purchased these spectacles for $100 (US$200 adjusted to 2023 value), would you be happy with them?'Results: There was a significant difference between the preferred and non-preferred prescriptions for the subjective quality of distance vision rating (medians 9 vs. 8; Z = -7.80, p < 0.0001) and ease of adaptation rating (medians 8 vs. 5; Z = -8.32, p < 0.0001) but the distance binocular visual acuity was not significantly different (both means = -0.09 logMAR; Z = -0.60, p = 0.55). Of all participants, 94% preferred the prescription deemed easier to adapt to but only 59% preferred the prescription with better subjective quality of distance vision and best visual acuity.Conclusion: Distance visual acuity was not found to be a useful predictor of participant preference to a new prescription and is likely over-relied upon in practice. The results support the adjustment of the subjective prescription where appropriate to aid patient adaptation and comfort.Keywords
Funding Information
- the Hoya Corporation of Japan and NEI Training
This publication has 22 references indexed in Scilit:
- Statistical guidelines for the analysis of data obtained from one or both eyesOphthalmic and Physiological Optics, 2012
- Evaluation of the Clinical Maxim: “If It Ain't Broke, Don't Fix It”Optometry and Vision Science, 2012
- Spectacle prescribing II: practitioner experience is linked to the likelihood of suggesting a partial prescriptionOphthalmic and Physiological Optics, 2011
- A Relationship between Tolerance of Blur and PersonalityInvestigative Ophthalmology & Visual Science, 2010
- Investigation of the causes of non-tolerance to optometric prescriptions for spectaclesOphthalmic and Physiological Optics, 2010
- Improving Vision to Prevent Falls in Frail Older People: A Randomized TrialJournal of the American Geriatrics Society, 2007
- Prescribing spectacles: reasons for failure of spectacle lens acceptanceOphthalmic and Physiological Optics, 2005
- Visual illusions? Beliefs and behaviours of presbyope clients in optometric practicePatient Education and Counseling, 2005
- Repeated Visual Acuity Measurement: Establishing the Patient??s Own Criterion for ChangeOptometry and Vision Science, 1993
- The use of accurate visual acuity measurements in clinical anti‐cataract formulation trialsOphthalmic and Physiological Optics, 1988