Rapid Multianalyte Microfluidic Homogeneous Immunoassay on Electrokinetically Driven Beads
Open Access
- 21 December 2020
- journal article
- research article
- Published by MDPI AG in Biosensors
- Vol. 10 (12) , 212
Abstract
The simplicity of homogeneous immunoassays makes them suitable for diagnostics of acute conditions. Indeed, the absence of washing steps reduces the binding reaction duration and favors a rapid and compact device, a critical asset for patients experiencing life-threatening diseases. In order to maximize analytical performance, standard systems employed in clinical laboratories rely largely on the use of high surface-to-volume ratio suspended moieties, such as microbeads, which provide at the same time a fast and efficient collection of analytes from the sample and controlled aggregation of collected material for improved readout. Here, we introduce an integrated microfluidic system that can perform analyte detection on antibody-decorated beads and their accumulation in confined regions within 15 min. We employed the system to the concomitant analysis of clinical concentrations of Neutrophil Gelatinase-Associated Lipocalin (NGAL) and Cystatin C in serum, two acute kidney injury (AKI) biomarkers. To this end, high-aspect-ratio, three-dimensional electrodes were integrated within a microfluidic channel to impart a controlled trajectory to antibody-decorated microbeads through the application of dielectrophoretic (DEP) forces. Beads were efficiently retained against the fluid flow of reagents, granting an efficient on-chip analyte-to-bead binding. Electrokinetic forces specific to the beads’ size were generated in the same channel, leading differently decorated beads to different readout regions of the chip. Therefore, this microfluidic multianalyte immunoassay was demonstrated as a powerful tool for the rapid detection of acute life-threatening conditions.Keywords
Funding Information
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (514247)
This publication has 43 references indexed in Scilit:
- Serum cystatin C as a marker of renal function in detection of early acute kidney injuryIndian Journal of Nephrology, 2013
- Overcoming the Effects of Matrix Interference in the Measurement of Urine Protein AnalytesBiomarker Insights, 2012
- Biomarkers of kidney injuryBiomarkers, 2011
- Antibody-Based Protein Multiplex Platforms: Technical and Operational ChallengesClinical Chemistry, 2010
- Detection of pesticide residues using an immunodevice based on negative dielectrophoresisBiosensors and Bioelectronics, 2009
- Neutrophil gelatinase‐associated lipocalin (NGAL): A new marker of kidney diseaseScandinavian Journal of Clinical and Laboratory Investigation, 2008
- Bead-based immunoassays using a micro-chip flow cytometerLab on a Chip, 2007
- Multiplexed protein measurement: technologies and applications of protein and antibody arraysNature Reviews Drug Discovery, 2006
- Modeling and Optimization of High-Sensitivity, Low-Volume Microfluidic-Based Surface ImmunoassaysBiomedical Microdevices, 2005
- Point of care testingBMJ, 2001