Methodology for Measuring the In Vitro Seating and Unseating Forces of Prefabricated Attachment Systems Used to Retain Implant Overdentures
Authors:
- 1 February 2010
- journal article
- research article
- Published by Wiley in Journal of Prosthodontics
- Vol. 19 (2) , 87-94
Abstract
The purpose of this in vitro investigation was to measure the forces generated during the continuous seating and unseating of prefabricated attachment systems used to retain implant overdentures. An experimental design consisting of interchangeable fixture mounts, a radially indexable fixture holder, and a materials testing systems (MTS) machine was used to measure forces generated during the insertion and removal of spherical stud attachments (Straumann, Inc, Waltham, WA). Three separate experiments were conducted measuring the seating and unseating forces of a vertically aligned patrix/matrix assembly, a 20 degrees angled patrix opposing a vertically positioned matrix, and a vertically positioned patrix opposing a 20 degrees angled matrix. For each patrix/matrix combination, three specimens were tested. Measurements were continuously recorded under reproducible conditions in the presence of artificial saliva. All specimens were subjected to 10,000 seating/unseating cycles. Statistical analysis was performed with rank analysis of variance (ANOVA) for a group comparison (alpha= 0.05). Results showed variability in the initial insertion and removal forces among experimental groups and among specimens within each experiment. A marked increase in the seating and unseating forces was recorded for all specimens during the first 300 cycles, followed by a gradual decrease in these forces. The exact p-values for the Kruskal-Wallis test showed no significant difference between the initial and final seating/unseating forces (p > 0.1) nor in the maximum seating/unseating forces (p > 0.6) among the three experimental groups. Spherical stud attachments exhibited consistent seating and unseating forces over 10,000 cycles. A 20 degrees angle between the patrix and matrix had no effect on the overall seating and unseating force values.Keywords
This publication has 17 references indexed in Scilit:
- Effect of Implant Angulation upon Retention of Overdenture AttachmentsJournal of Prosthodontics, 2005
- Management of the edentulous patientClinical Oral Implants Research, 2000
- Retention of prefabricated attachments for implant stabilized overdentures in the edentulous mandible: An in vitro studyThe Journal of Prosthetic Dentistry, 1998
- Patient satisfaction with implant-supported mandibular overdenturesInternational Journal of Oral and Maxillofacial Surgery, 1997
- 3‐D in vivo force measurements on mandibular implants supporting overdentures. A comparative study.Clinical Oral Implants Research, 1996
- Non‐submerged osseointegrated dental implants with ball attachments supporting overdentures in patients with mandibular alveolar ridge atrophy. A short‐term follow up.Clinical Oral Implants Research, 1996
- Prospective clinical evaluation of mandibular implant overdentures: Part II—patient satisfaction and preferenceThe Journal of Prosthetic Dentistry, 1995
- Problems with prostheses on implants: A retrospective studyThe Journal of Prosthetic Dentistry, 1994
- Peri‐implant mucosal aspects of ITI implants supporting overdentures. A five‐year longitudinal study.Clinical Oral Implants Research, 1994
- Retention and wear of precision-type attachmentsThe Journal of Prosthetic Dentistry, 1983