Prediction of Postoperative Knee Flexion in Insall-Burstein II Total Knee Arthroplasty
Authors:
- Amir MatityahuAMAmir Matityahu
- Stuart B. GoodmanStuart B. Goodman
- William MaloneyWMWilliam Maloney
- Steven WoolsonSWSteven Woolson
- Hong ShiHSHong Shi
- Daniel A. BlochDBDaniel A. Bloch
- 1 August 1998
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 353 (353) , 175-184
Abstract
Postoperative knee flexion in patients undergoing Insall-Burstein-II total knee arthroplasty at 2 years was evaluated regarding two basic questions: what groups of patients gain or lose the most flexion and what groups of patients have the best or worst postoperative flexion. Thirteen preoperative variables (maximum flexion, flexion arc, tibiofemoral angle, quadriceps strength, extensor lag, Knee Society score, Knee Society patient assessment, gender, age, height, weight, diagnosis, and surgeon) and four postoperative variables (leg length change, tibiofemoral angle, distance from patella to the joint line, and the tibial prosthesis anteroposterior translation on a lateral radiograph) were used in an attempt to explain postoperative flexion. The analysis was performed on 164 consecutive Insall-Burstein-II total knees in which the data were gathered prospectively on a time oriented medical record database. A regression tree analysis was used to identify several groups of patients, characterized by preoperative factor values, who had markedly above average performance on postoperative flexion. The preoperative factors identified include preoperative flexion, flexion arc, tibiofemoral angle, extensor lag, diagnosis, and age. The only postoperative variable of significance was tibiofemoral angle. Among the potential determinants of postoperative flexion that failed to appear predictive were the Knee Society scores and surgeon. Preoperative flexion is known to be a critical determinant of postoperative flexion in total knee replacement. However, in the current study, preoperative flexion accounted for only half of the difference between the best (122°) and the worst (88°) group, as determined with regression tree analysis.Keywords
This publication has 16 references indexed in Scilit:
- The posterior stabilized total knee prosthesis. Assessment of polyethylene damage and osteolysis after a ten-year-minimum follow-up.Journal of Bone and Joint Surgery, 1995
- Total Knee Arthroplasty in the Very AgedClinical Orthopaedics and Related Research, 1995
- Primary total knee arthroplasty in the elderlyThe Journal of Arthroplasty, 1994
- Factors affecting the range of movement of total knee arthroplastyThe Journal of Bone and Joint Surgery. British volume, 1993
- Total knee arthroplasty in patellectomized patientsThe Journal of Arthroplasty, 1993
- The Effects of Implant Design on Range of Motion After Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1992
- Range of motion after total condylar knee arthroplastyArchives of orthopaedic and trauma surgery, 1992
- Total knee arthroplasty with the kinematic prosthesis. Results after five to nine yearsJournal of Bone and Joint Surgery, 1990
- Posteriorly stabilised total-condylar knee replacement. Three to eight years' follow-up of 85 kneesThe Journal of Bone and Joint Surgery. British volume, 1988
- Effect of range of motion on the success of a total knee arthroplastyThe Journal of Arthroplasty, 1987