SEC Molecular-Weight-Sensitive Detection
Author:
- 1 January 2004
- journal article
- research article
- Published by Taylor & Francis in International Journal of Polymer Analysis and Characterization
- Vol. 9 (1-3) , 97-135
Abstract
In addition to an updated view of the basic principles of viscometry and elastic light scattering molecular-weight-sensitive detectors for size-exclusion chromatography (SEC), this review also examines many of the specific applications described in publications since 2001. These include the use of multidetector systems for validating SEC fractionation, examining polymer conformation, quantifying many forms of polymer topology (e.g., branching), physiochemical studies (e.g., phase separation and aggregation), analyzing oligomers, assessing polymer optical anisotropy, and estimating second virial coefficients. Although multidetector SEC is not without sources of error and uncertainty, it has developed into an extremely powerful analytical method that is increasingly used to accomplish diverse and difficult polymer analyses.Keywords
This publication has 160 references indexed in Scilit:
- Molecular characterization of α,β-poly(N-2-hydroxyethyl)-dl-aspartamide derivatives as potential self-assembling copolymers forming polymeric micellesPolymer, 2003
- Analysis of copolymers of styrene and methyl methacrylate using size exclusion chromatography with multiple detectionPhysical Chemistry Chemical Physics, 2002
- Solution Properties of Poly(N-vinylcarbazole) and Its Copolymers with Methyl MethacrylateMacromolecules, 2002
- New approaches using MW-sensitive detectors in GPC–TREF for polyolefin characterizationPolymer, 2001
- Core-Functionalized Star Polymers by Transition Metal-Catalyzed Living Radical Polymerization. 1. Synthesis and Characterization of Star Polymers with PMMA Arms and Amide CoresMacromolecules, 2001
- Dilute solution properties of lactosylated polyamidoamine dendrimers and their structural characteristicsPolymer, 2001
- Study of Rodlike Homopolypeptides by Gel Permeation Chromatography with Light Scattering Detection: Validity of Universal Calibration and Stiffness AssessmentMacromolecules, 2000
- SEC–viscometer detector systems. I. Calibration and determination of mark–houwink constantsJournal of Applied Polymer Science, 1993
- [28] Membrane protein molecular weight determined by low-angle laser light-scattering photometry coupled with high-performance gel chromatography1989
- Unperturbed Dimension and Translational Friction Constant of Branched PolymersThe Journal of Chemical Physics, 1964