Evaluation of plan quality, safety, and toxicity of brachytherapy for locally advanced cervical cancer in an Australian setting following changes in prescription and applicator design
- 12 December 2024
- journal article
- research article
- Published by Wiley in Journal of Medical Imaging and Radiation Oncology
- Vol. 69 (2) , 295-303
Abstract
Introduction: Chemoradiotherapy with MRI‐guided brachytherapy boosts is the standard of care for locally advanced cervical cancer. Data from the RetroEMBRACE and EMBRACE I trials provide dose‐response curves for target volumes and OAR. This study evaluated plan quality, safety and toxicity following escalation of the CTV_HR D90 prescription from 80–90 Gy to 85–95 Gy for two different applicator designs.Methods: A retrospective dosimetric plan quality review was undertaken for consecutively treated locally advanced cervical cancer brachytherapy boosts between 2017 and 2022, and the relationships between implant total reference air kerma (TRAK), CTV_HR volume and vaginal dose were investigated. Safety and ≤grade 3 toxicity results were evaluated.Results: Seventy patients were identified. All patients received a CTV_HR D90 dose >85 Gy and rectum D2cm3 of 3 <90 Gy. Needles were used in 48.6% of patients, and the mean percentage needle TRAK was 38.2%. Increasing the percentage of needle TRAK decreased vaginal TRAK. Sixty‐three patients had more than 12 months of follow‐up (median 27 months). From this cohort, grade 3 or higher toxicity for vaginal, genitourinary, gastrointestinal and fistula events were seen in 3.2%, 1.6%, 0% and 3.2% of patients, respectively.Conclusion: Increased dose prescriptions and a change of applicator design were successfully adopted into an Australian practice. Applicator design and interstitial needle use affect the plan quality and ability to meet OAR dose constraints following target dose escalation. No safety concerns with needle use or dose escalation were identified.Keywords
This publication has 22 references indexed in Scilit:
- Ring Versus Ovoids and Intracavitary Versus Intracavitary-Interstitial Applicators in Cervical Cancer Brachytherapy: Results From the EMBRACE I StudyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2020
- Assessment of dose to functional sub-structures in the lower urinary tract in locally advanced cervical cancer radiotherapyPhysica Medica, 2019
- The EMBRACE II study: The outcome and prospect of two decades of evolution within the GEC-ESTRO GYN working group and the EMBRACE studiesClinical and Translational Radiation Oncology, 2018
- Total reference air kerma can accurately predict isodose surface volumes in cervix cancer brachytherapy. A multicenter studyBrachytherapy, 2017
- Association of bladder dose with late urinary side effects in cervical cancer high-dose-rate brachytherapyBrachytherapy, 2017
- Recommendations from Gynaecological (GYN) GEC-ESTRO Working Group (IV): Basic principles and parameters for MR imaging within the frame of image based adaptive cervix cancer brachytherapyRadiotherapy and Oncology, 2012
- Dose Effect Relationship for Late Side Effects of the Rectum and Urinary Bladder in Magnetic Resonance Image-Guided Adaptive Cervix Cancer BrachytherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Clinical outcome of protocol based image (MRI) guided adaptive brachytherapy combined with 3D conformal radiotherapy with or without chemotherapy in patients with locally advanced cervical cancerRadiotherapy and Oncology, 2011
- Recommendations from gynaecological (GYN) GEC ESTRO working group (II): Concepts and terms in 3D image-based treatment planning in cervix cancer brachytherapy—3D dose volume parameters and aspects of 3D image-based anatomy, radiation physics, radiobiologyRadiotherapy and Oncology, 2006
- Recommendations from Gynaecological (GYN) GEC-ESTRO Working Group☆ (I): concepts and terms in 3D image based 3D treatment planning in cervix cancer brachytherapy with emphasis on MRI assessment of GTV and CTVRadiotherapy and Oncology, 2005