The LANSCE accelerator is currently powered by a filament-driven, biased converter-type H− ion source that operates at 10%, the highest plasma duty factor for this type of source, using only ∼2.2 SCCM of H2. The ion source needs to be replaced every 4 weeks, which takes up to 4 days. The measured negative beam current of 12–16 mA falls below the desired 24 mA acceptance of the LANCSE accelerator. The SNS (Spallation Neutron Source) RF-driven, H− ion source injects ∼50 mA of H− beam into the SNS accelerator at 60 Hz with a 6% duty factor and an availability of >99.5% but requires ∼30 SCCM of H2. Up to 7 A h of H− have been produced during the 14-weeks-long source service cycles, which is unprecedented for small emittance, high-current, pulsed H− ion sources. The emittance of the SNS source is slightly smaller than the emittance of the LANSCE source. The SNS source also features unrivaled low Cs consumption and can be installed and started up in − ion sources on the LANSCE accelerator because they could (a) fill the LANSCE accelerator to its capacity, (b) decrease the source replacement time by a factor of up to 7, and (c) increase source lifetime by a factor of about 4. This paper discusses some of the challenges that emerge when trying to match a different H− source into an existing injector with significantly different characteristics and operating regimes.Keywords
Funding Information
- U.S. Department of Energy (AC05-00OR22725, DE-AC52-06NA25396)
This publication has 13 references indexed in Scilit:
- LANSCE Accelerator Update and Future PlansJournal of Physics: Conference Series, 2018
- Record productions establish RF-driven sources as the standard for generating high-duty-factor, high-current H− beams for accelerators (Winner of the ICIS 2017 Brightness Award)Review of Scientific Instruments, 2018
- Different approaches to modeling the LANSCE H− ion source filament performanceReview of Scientific Instruments, 2015
- The Spallation Neutron Source accelerator system designNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2014
- Towards Understanding the Cesium Cycle of the Persistent H[sup −] Beams at SNSAIP Conference Proceedings, 2011
- Ramping up the Spallation Neutron Source beam power with the H− source using 0 mg Cs/dayReview of Scientific Instruments, 2010
- Ramping Up the SNS Beam Power with the LBNL Baseline H[sup −] Source2009
- Physical Insights and Test Stand Results for the LANSCE H− Surface Converter SourceAIP Conference Proceedings, 2005
- Design, Operational Experiences and Beam Results Obtained with the SNS H− Ion Source and LEBT at Berkeley LabAIP Conference Proceedings, 2002