Optical test procedure for characterization and calibration of robotic fiber positioners for multiobject spectrographs

Authors:

Abstract
An increasing demand for massive spectroscopic surveys has led to the development of several new multiobject spectrograph (MOS) projects. These instruments are capable of measuring the spectra of hundreds of galaxies or stars simultaneously, whereas several have already been built (e.g., Sloan Digital Sky Survey/Baryon Oscillation Spectroscopic Survey,1 Large Sky Area Multi-object Fibre Spectroscopic Telescope,2 Multi-Espectrógrafo en GTC de Alta Resolución para Astronomía (MEGARA),3 and TAIPAN4) many are currently under development (e.g., dark energy spectroscopic instrument (DESI),5 prime focus spectrograph (PFS),6 WHT enhanced area velocity explorer,7 multiobject optical and near-infrared spectrograph (MOONS),8 and 4-metre multi-object spectroscopic telescope9). All these new robotic fiber-fed instruments rely on small, high-precision mechanisms for the accurate positioning of optical fibers. In order to capture the light of the stars or galaxies, the fiber ends are precisely positioned at the telescope’s focal surface, such that the fiber cores match their designated targets on the sky. One successful positioning approach is the use of robotic positioners with two axes of rotation such as used for MEGARA,10 MOONS,11 PFS,12,13 DESI,14,15 and more recently for SDSS-V16 and also proposed by others.17 – 24 These positioners carry out Cartesian (x,y) planar movements using two actuated rigid arms serially linked. They have SCARA-like kinematics with two motorized rotational joints. A sketch is shown in Fig. 1. By commanding the motors, the fiber ends can accurately be maneuvered to their targets on the focal surface. Instrument performance depends largely on x,y position precision and correct angular alignment of the fiber ends. Fiber positioning errors and fiber end misalignment lead to a throughput loss due to vignetting and focal ratio degradation, respectively. Therefore, the pointing performance of every single positioner has to be verified and crucial parameters have to be characterized in order to ensure accurate positioning and alignment. Furthermore, the number of positioners used in a single telescope has been steadily increasing and ranges in recent project from 500 (SDSS-V) up to 5000 (DESI) units. It is to be expected that this number will continue to grow for future projects. Therefore, it is important to facilitate quality control and to minimize overall verification and characterization time per positioner.
Funding Information
  • Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (20FL21-166919)
  • Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (20FL21-185771)
  • Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (20FL21-160476)